Catheter pose-dependent virtual angioscopy images visualized on augmented reality glasses

Author:

Haxthausen Felix von1,Jäckle Sonja2,Strehlow Jan2,Ernst Floris1,García-Vázquez Verónica1

Affiliation:

1. Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck , Germany

2. Fraunhofer MEVIS – Institute for Digital Medicine, Lübeck/ Bremen , Germany

Abstract

Abstract Fluoroscopy and digital subtraction angiography provide guidance in endovascular aortic repair (EVAR) but introduce radiation exposure and require the administration of contrast agent. To overcome these disadvantages, previous studies proposed to display the pose of an electromagnetically (EM) tracked catheter tip within a three-dimensional virtual aorta on augmented reality (AR) glasses. For further guidance, we propose to create virtual angioscopy images based on the catheter tip pose within the aorta and to display them on HoloLens. The aorta was segmented from the computed tomography (CT) data using MeVisLab software. A landmarkbased registration allowed the calculation of the pose of the EM sensor in the CT coordinate system. The sensor pose was sent to MeVisLab running on a computer and a virtual angioscopy image was created at runtime based on the segmented aorta. When requested by HoloLens, the last encoded image was sent from MeVisLab to the AR glasses via Wi-Fi using a remote procedure call (gRPC), and then decoded and displayed on HoloLens. For evaluation purposes, the latency of transmitting and displaying the images was measured using two different lossy compression formats (namely JPEG and DXT1). A mean latency of 82 ms was measured for the JPEG format. On the other hand, using the DXT1 format, the mean latency was reduced by 87 %. This study proved the feasibility of creating pose-dependent virtual angioscopy images and displaying them on HoloLens. Additionally, the results showed that the DXT1 format outperformed the JPEG format regarding latency. The virtual angioscopy may add valuable additional information for guidance in radiation-sparing EVAR procedure approaches.

Publisher

Walter de Gruyter GmbH

Subject

Biomedical Engineering

Reference8 articles.

1. Least - squares fitting of two D point sets;Arun;IEEE Trans Pattern Anal Mach Intell,1987

2. al In vitro three - dimensional aortic vasculature modeling based on sensor fusion between intravascular ultrasound and magnetic tracker;Shi;Int J Med Robotics Comput Assist Surg,2012

3. Electromagnetic tracking for registration and nav - igation in endovascular aneurysm repair : A phantom study;De Lambert;Eur J Vasc Endovasc Surg,2012

4. von Navigation and visu - alisation with HoloLens in endovascular aortic repair;García;Innov Surg Sci,2018

5. Development of a test and training envi - ronment for endovascular aortic procedures using rapid pro - totyping as part of NAV - EVAR project;Bouchagiar;Eur J Vasc Endovasc Surg,2018

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3