Power Factor (PF) correction is a major power quality function in electrical distribution systems. This paper proposes a low-cost Automatic Power Factor Correction (APFC) system to increase the PF of both lagging and leading single-phase loads. The Arduino Mega 2560 microcontroller was used to calculate the PF and activate the relays that connect the capacitor/inductor banks to the load in parallel. Thus, the required capacitive or inductive reactive power was produced by the APFC system by automatically connecting the capacitor/inductor banks to the load in parallel. The APFC system can also measure and display many electrical parameters of the load such as the rms voltage, the rms current, PF, and the real, reactive, and apparent power on an LCD display. Two zero-crossing detector circuits are used to find the phase angle difference between voltage and current waveforms of the load. The measurement ability of the APFC system was tested for resistive, inductive, and capacitive loads with two different sizes. The measurement results were compared with the measurements of a commercial digital power meter and a measurement error of less than 8.0% was observed. The PF correction ability of the APFC system was verified for inductive and capacitive loads with two different sizes. The experiments show that the PF increased to close to unity for both lagging and leading loads.
Publisher
Engineering, Technology & Applied Science Research
Reference13 articles.
1. [1] S. Mane, R. Sapat, P. Kor, J. Shelar, R. D. Kulkarni, and J. Mundkar, "Microcontroller based Automatic Power Factor Correction System for Power Quality Improvement," in 2020 International Conference for Emerging Technology (INCET), Jun. 2020, pp. 1-6.
2. [2] M. M. Uddin, A. A. Mahmud, and N. Islam, "Design Implementation of a Microcontroller Based Automatic Power Factor Rectification System for Different Loads," in 2019 1st International Conference on Advances in Science, Engineering and Robotics Technology (ICASERT), May 2019, pp. 1-6.
3. [3] M. S. Zaky, H. Z. Azazi, and E. Touti, "PFC Control for LED Lamp Driver Using Sensorless Predictive Current Controller," Engineering, Technology & Applied Science Research, vol. 8, no. 5, pp. 3373-3379, Oct. 2018.
4. [4] A. Tsolov and B. Marinova, "Optimal Power Factor for the Reactive Load of Small Hydro Power Plants," Engineering, Technology & Applied Science Research, vol. 8, no. 2, pp. 2755-2757, Apr. 2018.
5. [5] A. Kayabaşi and R. Akkaya, "The design and implementation of a microcontroller-based single phase on- line uninterrupted power supply with power factor correction," in 2009 International Conference on Electrical and Electronics Engineering - ELECO 2009, Bursa, Turkey, Nov. 2009, pp. I-442-I-446.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献