Abstract
In this paper, a sensitive constrained integer linear programming approach is formulated for the optimal allocation of Phasor Measurement Units (PMUs) in a power system network to obtain state estimation. In this approach, sensitive buses along with zero injection buses (ZIB) are considered for optimal allocation of PMUs in the network to generate state estimation solutions. Sensitive buses are evolved from the mean of bus voltages subjected to increase of load consistently up to 50%. Sensitive buses are ranked in order to place PMUs. Sensitive constrained optimal PMU allocation in case of single line and no line contingency are considered in observability analysis to ensure protection and control of power system from abnormal conditions. Modeling of ZIB constraints is included to minimize the number of PMU network allocations. This paper presents optimal allocation of PMU at sensitive buses with zero injection modeling, considering cost criteria and redundancy to increase the accuracy of state estimation solution without losing observability of the whole system. Simulations are carried out on IEEE 14, 30 and 57 bus systems and results obtained are compared with traditional and other state estimation methods available in the literature, to demonstrate the effectiveness of the proposed method.
Publisher
Engineering, Technology & Applied Science Research
Reference31 articles.
1. K. E. Martin, D. Hamai, M. G. Adamiak, S. Anderson, M. Begovic, G. Benmouyal, G. Brunello, J. Burger, J. Y. Cai, B. Dickerson, V. Gharpure, B. Kennedy, D. Karlsson, A. G. Phadke, J. Salj, V. Skendzic, J. Sperr, Y. Song, C. Huntley, B. Kasztenny, E. Price, “Exploring the IEEE Standard C37.118-2005 synchrophasors for power systems”, IEEE Transactions on Power Delivery, Vol. 23, No. 4, pp. 1805-1811, 2008 2. L. L. Lai, H. T. Zhang, S. Mishra, D. Ramasubramanian, C. S. Lai, F. Y. Xu, “Lessons Learned from July 2012 Indian Blackout”, 9th IET International Conference on Advances in Power System Control, Operation and Management, pp. 1-6, 2012 3. T. Moger, T. Dhadbanjan, “A novel index for identification of weak nodes for reactive compensation to improve voltage stability IET Generation, Transmission & Distribution, Vol. 9, No. 14, pp. 1826-1834, 2015 4. F. Capitanescu, T. V. Cutsem, “Unified sensitivity analysis of unstable or low voltages caused by load increases or contingencies”, IEEE Transactions on Power Systems, Vol. 20, No. 1, pp. 321-329, 2005. 5. V. Balamourougan, T. S. Sidhu, M. S. Sachdev, “Technique for online prediction of voltage collapse IEE Proceedings - Generation, Transmission and Distribution, Vol. 151, No. 4, pp. 453-460, 2004
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|