Visual Functions after Implantation of Acrysof Monofocal Intraocular Lenses

Author:

Lešták Ján,Pitrová Šárka,Žáková Markéta,Fůs Martin,Hallová Helena,Marešová Klára

Abstract

Purpose: The purpose of the study was to evaluate the visual functions after implantation of Acrysof monofocal intraocular lenses Alcon (SA60AT. MA50BM a SN60WF a SN6AT). Materials and methods: Four works are presented in the overview. The first work deals with the effect of eye length. corneal optic power and anterior chamber depth on the uncorrected near visual acuity (UNVA) after IOL implantation. The second work compares the effect of eye position (horizontal and vertical) on the final UNVA. The third work deals with the influence of the spherical lenses (SA and MA) and yellow aspherical lenses (SN) on UNVA. The later work examines the effect of pupil width on UNVA. Results: The first work showed the dependence of eye axial length (the largest in eyes bellow 22.5 mm. r = 0.36) on UNVA. 77.4 % of eyes with axial length below 22.5 mm had UNVA better than 0.5 and 70.49 % of all evaluated eyes had UNVA better than 0.5. Uncorrected far visual acuity (UDVA) better than 1.0 was in 97.54 % eyes in the whole group. In the second work we found a mean correlation in eyes shorter than 22.5 mm with UNVA in horizontal position (r = 0.39) and in the vertical position (r = 0.49). UNVA improved in these eyes in horizontal position from 0.53 to 0.58 in vertical position of the eye. In all eyes from the group UNVA changed from 0.51 to 0.56. The third work demonstrated the effect of sphericity and chromaticity on UNVA. Better than 0.5 in the group of eyes shorter than 22.5 mm in SA IOL in 67 % and in SN IOL in 60 %. In eyes with mean axial length was UNVA better than 0.5 in SA IOL in 86.5 %. in MA IOL in 81 % and in SN IOL in 75 %. In eyes longer than 23.5 mm was UNVA better than 0.5 in SA IOL in 100 % of eyes, in MA IOL in 60 % and in SN IOL in 33 % of eyes. In the fourth work the effect of pupil size was not demonstrated. Conclusion: The works showed excellent results of UNVA and UDVA after implantation of Acrysof monofocal lenses.

Publisher

Czech Society of Ophthalmology of the CzMA

Subject

Ophthalmology

Reference17 articles.

1. Benjamin WJ. Borish´s Clinical Refraction, 2006, Elseviever, ISBN-13: 978-0-7506-7524-6

2. Urminský J, Rozsíval P, Feuermannová A, Lorencová V, Jirásková N. Implantace multifokální nitrooční čočky. [Implantation of multifocal intraocular lenses]. Cesk Slov Oftalmol. 2004;60:30–36. Czech.

3. Cochener B, Fernández-Vega L, Alfonso JF, Maurel F, Meunier J, Berdeaux G. Spectacle independence and subjective satisfaction of ResTOR® multifocal intraocular lens after cataract or presbyopia surgery in two european countries, Clin Ophthalmol. 2010;4:81-89.

4. Marešová K, Mlčák P, Vláčil O. Výsledky operací katarakty s implantací Acrysof ReSTOR SN6AD3. [Results of the cataract with the Acrysof ReSTOR SN6AD3 intraocular lens implantation]. Cesk Slov Oftalmol. 2010;66:26-28. Czech

5. Veliká V, Hejsek L, Raiskup F. Clinical Results of the Implantation Two Types of Multifocal Rotational Asymmetric Intraocular Lenses. Cesk Slov Oftalmol. 2017;73:3-12. Available from: http..//www.cs-ophthalmologz.cz/en/journal/articles/13