PREDICTORS OF COMPUTERIZED ELECTROACUPUNCTURE EFFICACY IN BRONCHIAL ASTHMA TREATMENT

Author:

Golubtsova Tat'yana Sergeevna1ORCID,Yudina Elena Evgen'evna1ORCID,Pribylova Svetlana Alekseevna1ORCID,Kerova Irina Rinatovna1ORCID,Peskov Andrey Borisovich1ORCID,Volkov Maksim Anatol'evich1ORCID,Khokhlov Mikhail Pavlovich1ORCID,Kostishko Boris Mikhaylovich1ORCID

Affiliation:

1. Ulyanovsk State University

Abstract

The aim of the study is to evaluate the significance of the initial clinical parameters of patients with bronchial asthma while predicting the efficacy of computerized electroacupuncture (CEAP). Materials and Methods. The two-stage study included 120 patients with bronchial asthma (BA). During the first stage, group OI underwent 3 CEAP monthly courses, while group P was treated with standard pharmacotherapy. Based on the results of the first study stage, patients were included in group OII, which consisted of a subgroup with expected good CEAP efficacy (group OII1) and a subgroup with expected insufficient CEAP efficacy (group OII2). Group OII underwent 3 monthly CEAP courses, which consisted of five daily events. Results. After three CEAP courses, group OI demonstrated a high proportion of patients with good and complete BA control. According to asthma controllability, patients were stratified into 4 subgroups: OI1 – patients of the main group 1 with improved disease control (n=20); OI2 – patients of the main group 1 with unchanged disease control (n=20); P1 – patients of the reference group with improved disease control (n=10); Р2 – patients of the reference group with unchanged disease control (n=30). The retrospective analysis showed no significant differences between respiratory function parameters in CT 1 and 2 in groups OI1 and OI2. The authors analyzed electrical resistance (ER) dynamics of all biologically active points (BAP) during the first CEAP course in group OI: the difference between the total indicators of the initial and final ER of all BAPs gradually increased. Thus, we considered it possible to apply ES indicators of BAPs to predict CEAP efficacy. There was a correlation between BA controllability and ES of BAT, as registered in the first two CEAP sessions in group OI. It was supposed to calculate the indicator of the expected treatment efficacy (IETE). IETE predicted negative treatment outcomes in 100 % of cases (sensitivity – 100 %, specificity – 100 %). Prediction of a positive effect was less accurate: sensitivity – 70 %, specificity – 80 %. The sensitivity of the prediction of dynamics absence was 80 %, specificity – 70 %. Conclusion. It is inappropriate to use the initial parameters of respiratory function as predictors of CEAP efficacy in BA treatment. IETE is an objective measurable indicator of BAPs and can be used to predict CEAP efficacy in BA treatment.

Publisher

Ulyanovsk State University

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3