Investigating sensor location on the effectiveness of continuous glucose monitoring during exercise in a non‐diabetic population

Author:

Coates Alexandra M.1ORCID,Cohen Jeremy N.1,Burr Jamie F.12

Affiliation:

1. The Human Performance and Health Research Laboratory Department of Human Health and Nutritional Sciences University of Guelph Guelph Canada

2. Animal Science and Nutrition, University of Guelph Guelph Canada

Abstract

ABSTRACTThe purpose of this investigation was to evaluate whether continuous glucose monitoring (CGM) sensors worn on the active muscle may provide enhanced insight into glucose control in non‐diabetic participants during cycling exercise compared to traditional sensor placement on the arm. Data from 9 healthy participants (F:3) was recorded using CGM sensors on the arm (triceps brachii) and leg (vastus medialis) following 100 g glucose ingestion during 30 min experimental visits of: resting control, graded cycling, electrically stimulated quadriceps contractions, and passive whole‐body heating. Finger capillary glucose was used to assess sensor accuracy. Under control conditions, the traditional arm sensor better reflected capillary glucose, with a mean absolute relative difference (MARD) of 12.4 ± 9.3% versus 18.3 ± 11.4% in the leg (P = 0.02). For the intended use during exercise, the sensor‐site difference was attenuated, with similar MARDs during cycling (arm:15.5 ± 12% versus leg:16.7 ± 10.8%, P = 0.96) and quadriceps stimulation (arm:15.5 ± 14.8% versus leg:13.9 ± 9.5%, P = 0.9). At rest, glucose at the leg was consistently lower than the arm (P = 0.01); whereas, during graded cycling, the leg‐glucose was lower only after maximal intensity exercise (P = 0.02). There was no difference between sensors during quadriceps stimulation (P = 0.8). Passive heating caused leg‐skin temperature to increase by 3.1 ± 1.8°C versus 1.1 ± 0.72°C at the arm (P = 0.002), elevating MARD in the leg (23.5 ± 16.2%) and lowering glucose in the leg (P < 0.001). At rest, traditional placement of CGM sensors on the arm may best reflect blood glucose; however, during cycling, placement on the leg may offer greater insight to working muscle glucose concentrations, and this is likely due to greater blood‐flow rather than muscle contractions.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine,Physical Therapy, Sports Therapy and Rehabilitation,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3