Safety Assessment of Poloxamers 101, 105, 108, 122, 123, 124, 181, 182, 183, 184, 185, 188, 212, 215, 217, 231, 234, 235, 237, 238, 282, 284, 288, 331, 333, 334, 335, 338, 401, 402, 403, and 407, Poloxamer 105 Benzoate, and Poloxamer 182 Dibenzoate as Used in Cosmetics

Author:

Abstract

Poloxamers are polyoxyethlyene, polyoxypropylene block polymers. The impurities of commercial grade Poloxamer 188, as an example, include low-molecular-weight substances (aldehydes and both formic and acetic acids), as well as 1,4-dioxane and residual ethylene oxide and propylene oxide. Most Poloxamers function in cosmetics as surfactants, emulsifying agents, cleansing agents, and/or solubilizing agents, and are used in 141 cosmetic products at concentrations from 0.005% to 20%. Poloxamers injected intravenously in animals are rapidly excreted in the urine, with some accumulation in lung, liver, brain, and kidney tissue. In humans, the plasma concentration of Poloxamer 188 (given intravenously) reached a maximum at 1 h, then reached a steady state. Poloxamers generally were ineffective in wound healing, but were effective in reducing postsurgical adhesions in several test systems. Poloxamers can cause hypercholesterolemia and hypertriglyceridemia in animals, but overall, they are relatively nontoxic to animals, with LD50 values reported from 5 to 34.6 g/kg. Short-term intravenous doses up to 4 g/kg of Poloxamer 108 produced no change in body weights, but did result in diffuse hepatocellular vacuolization, renal tubular dilation in kidneys, and dose-dependent vacuolization of epithelial cells in the proximal convoluted tubules. A short-term inhalation toxicity study of Poloxamer 101 at 97 mg/m3 identified slight alveolitis after 2 weeks of exposure, which subsided in the 2-week postexposure observation period. A short-term dermal tox-icity study of Poloxamer 184 in rabbits at doses up to 1000 mg/kg produced slight erythema and slight intradermal inflammatory response on histological examination, but no dose-dependent body weight, hematology, blood chemistry, ororgan weight changes. A6-month feeding study in rats and dogs of Poloxamer 188 at exposures up to 5% in the diet produced no adverse effects. Likewise, Poloxamer 331 (tested up to 0.5 g/kg day-1), Poloxamer 235 (tested up to 1.0 g/kg day-1), and Poloxamer 338 (at 0.2 or 1.0 g/kg day-1) produced no adverse effects in dogs. Poloxamer 338 (at 5.0 g/kg day-1) produced slight transient diarrhea in dogs. Poloxamer 188 at levels up to 7.5% in diet given to rats in a 2-year feeding study produced diarrhea at 5% and 7.5% levels, a small decrease in growth at the 7.5% level, but no change in survival. Doses up to 0.5 mg/kg day-1 for 2 years using rats produced yellow discoloration of the serum, high serum alkaline phosphatase activity, and elevated serum glutamicpyruvic transaminase and glutamic-oxalacetic transaminase activities. Poloxamers are minimal ocular irritants, but are not dermal irritants or sensitizers in animals. Data on reproductive and developmental toxicity of Poloxamers were not found. An Ames test did not identify any mutagenic activity of Poloxamer 407, with or without metabolic activation. Several studies have suggested anti-carcinogenic effects of Poloxamers. Poloxamers appear to increase the sensitivity to anticancer drugs of multidrug-resistant cancer cells. In clinical testing, Poloxamer 188 increased the hydration of feces when used in combination with a bulk laxative treatment. Compared to controls, one study of angioplasty patients receiving Poloxamer 188 found a reduced myocardial infarct size and a reduced incidence of reinfarction, with no evidence of toxicity, but two other studies found no effect. Poloxamer 188 given to patients suffering from sickle cell disease had decreased pain and decreased hospitilization, compared to controls. Clinical tests of dermal irritation and sensitization were uniformly negative. The Cosmetic Ingredient Review (CIR) Expert Panel stressed that the cosmetic industry should continue to use the necessary purification procedures to keep the levels below established limits for ethylene oxide, propylene oxide, and 1,4-dioxane. The Panel did note the absence of reproductive and developmental toxicity data, but, based on molecular weight and solubility, there should be little skin penetration and any penetration of the skin should be slow. Also, the available data demonstrate that Poloxamers that are introduced into the body via routes other than dermal exposure have a rapid clearance from the body, suggesting that there would be no risk of reproductive and/or developmental toxicity. Overall, the available data do not suggest any concern about carcinogenesis. Although there are gaps in knowledge about product use, the overall information available on the types of products in which these ingredients are used, and at what concentration, indicates a pattern of use. Based on these safety test data and the information that the manufacturing process can be controlled to limit unwanted impurities, the Panel concluded that these Poloxamers are safe as used.

Publisher

SAGE Publications

Subject

Toxicology

Cited by 178 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3