Influence of ionic and non-ionic radiographic contrast media on leukocyte adhesion molecules

Author:

Vermeiren Guy L. J.12,Willems Roel3,Claeys Marc J.2,Vrints Chris2,Slegers Herman4,Jorens Philippe G.1

Affiliation:

1. Department of Intensive Care, University Hospital of Antwerp, Wilrijkstraat 10, Edegem, B 2650, Belgium

2. Department of Cardiology, University Hospital of Antwerp, Wilrijkstraat 10, Edegem, B 2650, Belgium

3. Laboratory of Experimental Hematology, University Hospital of Antwerp, Wilrijkstraat 10, Edegem, B 2650, Belgium

4. Laboratory of Cellular Biochemistry, Department of Biochemistry, University of Antwerp, Belgium

Abstract

Background:Many papers have focused on the importance of granulocytes in the process of reperfusion and ischemia. Most of the clinical studies measured several parameters of this process during and after coronary angiography, without taking into account the effect of the radiographic contrast media (RCM) used during this procedure.Materials and methods:We performed a randomized patient study(n=37)to evaluate the effect of ionic and non-ionic RCM on granulocyte adhesion during coronary angiography. We also evaluated the influence of the ionicity and osmolarity of the different substances on granulocyte adhesion molecules inin vitroexperiments.Results:The osmolarity of patient serum samples increased from 302±1 to 309±1 mOsm/kg(P<0.05)after infusion of RCM. The CD11b expression in the samples of the non-ionic RCM treated group increased from 221±21 MFI to 377±30 MFI(P<0.05)measured as the absolute mean fluorescence intensity (MFI), yet did not alter significantly in the ionic RCM group. In contrast, thein vitroexperiments showed a reduction of the CD11b expression from 360±70 MFI to 149±30 MFI(P<0.05)in the ionic RCM group.Conclusions:The upregulation of adhesion molecules was significantly reducedin vivowith ionic RCM, while ionic substances caused opposite effectsin vitro. This effect should be taken into account when performing leukocyte functional analysis of samples taken during angiography.

Publisher

Hindawi Limited

Subject

Cell Biology,Immunology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3