Incidence of ventricular fibrillation during left coronary arteriography in pigs: comparison of a solution of the nonionic dimer iodixanol with solutions of five different nonionic monomers

Author:

Chai C. M.1,Karlsson J. O. G.1,Almén T.1

Affiliation:

1. Department of Diagnostic Radiology and Department of Experimental Research, University Hospital Malmö, Medical Faculty, University of Lund, Malmö, Sweden;, Department of Pharmacology, University of Linköping, Linköping, Sweden

Abstract

Background: Solutions of iodine contrast media (CM) used for selective coronary arteriography (CA) should have minimal propensity to cause ventricular fibrillation (VF). Commonly used CM for CA are nonionic monomers or dimers. Purpose: To compare VF propensity of ready-to-use solutions of one nonionic dimer, iodixanol, and five nonionic monomers, iobitridol, iopamidol, iomeprol, iopromide, and ioversol. Material and Methods: Twenty milliliters of each CM was injected into the left coronary artery (LCA) through an inflated balloon catheter (0.5 ml/s) in 14 pigs; the longest period of injection was 40 s. If VF occurred before 40 s, the injection was stopped and the heart was defibrillated. After VF, there was a delay of 40 min before the next injection. Hemodynamic parameters and vector electrocardiography (VECG) were monitored. A CM with a lower frequency of VF and a longer period between start of injection and start of VF was considered to have a lower VF propensity. Results: Following 14 injections, each of the five nonionic monomers caused 14 VF, whereas iodixanol caused three VF ( P<0.01). When VF occurred after iodixanol, it occurred later than after the other CM ( P<0.001). Iodixanol caused less prolongation in QRS time ( P<0.01) and QTc time ( P<0.05) than the other CM. Prolongations in QRS and QTc times caused by CM parallel the VF propensities of the CM. Conclusion: Ready-to-use solutions of the dimer iodixanol have lower VF propensity than solutions of the five monomeric CM. This is related to the fact that the solutions of the dimer iodixanol have lower osmolality, higher viscosity, and higher concentrations of NaCl and CaCl2 than solutions of the five monomers.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3