Bolus compared with continuous infusion of microbubble contrast agent using real-time contrast harmonic imaging ultrasound in breast tumors

Author:

Saracco A.1,Aspelin P.1,Leifland K.2,Themudo R.3,Wilczek B.2,Axelsson R.1

Affiliation:

1. Division of Radiology, Department of Clinical Science, Intervention, and Technology (CLINTEC), Karolinska Institute, Stockholm, Sweden

2. Division of Radiology, Department of Breast Imaging, Unilabs Capio S:t Göran Hospital, Stockholm, Sweden

3. Department of Radiology, Hospital Geral Santo António, Porto, Portugal

Abstract

Background: Contrast-enhanced ultrasound (CEUS) has gained interest because of its ability to gather vascular information in various organs. There is still a matter of debate concerning its value in breast lesions. The method of choice on how to administer the contrast agent varies depending on the organ to be studied. Infusion of microbubbles is used in echocardiography, while bolus administration is the preferred technique for abdominal organs. Purpose: To compare—in equal doses—bolus versus continuous infusion of microbubbles, using real-time contrast harmonic imaging in breast tumors. Material and Methods: A total of 29 female patients (mean age 54 years) with either clear malignant or benign findings in the breast or axilla were included. Contrast harmonic imaging (CHI US) was performed with a Philips iU22 using an L9-3 MHz linear probe, especially designed for this purpose. A low mechanical index (0.06–0.07) was used to avoid massive destruction of the microbubbles. A dose of 2.4 ml of Sono Vue was first infused intravenously over 1 min with an infusion pump. After 10 min, the same dose was injected as a bolus over 2 s, followed by a flush of 10 ml of saline solution. Contrast uptakes by the tumors were recorded 2 min from the moment of injection, with both methods for each patient. Results: Bolus administration of contrast agent provided a sharply demarcated enhancement and wash-out pattern for all lesions. The continuous infusion of the same contrast agent failed to show any wash-in/wash-out or time-to-peak/peak intensity phenomena in all cases. Conclusion: CEUS using real-time harmonic imaging in order to evaluate breast tumors should be performed with bolus administration of contrast agent in order to achieve better intensity/time curve outcomes.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3