Optimization of computed tomography urography protocol, 1997 to 2008: Effects on radiation dose

Author:

Dahlman P.1,Jangland L.2,Segelsjö M.1,Magnusson A.1

Affiliation:

1. Department of Radiology, Uppsala University Hospital, Uppsala, Sweden

2. Department of Medical Physics, Uppsala University Hospital, Uppsala, Sweden

Abstract

Background: Since computed tomography (CT) urography began to replace excretory urography as the primary imaging technique in uroradiology, the collective radiation dose to the patients has increased. Purpose: To examine the changes in the CT urography protocol for investigating suspected urinary tract malignancy between the years 1997 and 2008, and how these changes have influenced the mean effective dose. Material and Methods: The study was based on 102 patients (mean age 66.1±14.8 years, range 31–89 years; 30 female, 72 male) divided into five groups (groups A–E) corresponding to the time points at which changes were made to the CT urography protocol. The mean effective doses were estimated using the ImPACT CT Patient Dosimetry Calculator. Results: The number of scan phases at CT urography was reduced from four to three in 1999, resulting in a reduction of the mean effective dose from 29.9/22.5 (female [F]/male [M]) mSv (group A) to 26.1/18.9 (F/M) mSv (group B). In 2001, mAs settings were adapted to patient size, and the mean effective dose was reduced to 16.8/12.0 (F/M) mSv (group C). In 2005, scans were performed with a multidetector-row CT equipped with automatic tube current modulation in the x- and y-axis (CARE Dose). The effective mAs was also lowered in the unenhanced and excretory phase, yet the mean effective dose increased to 18.2/13.1 (F/M) mSv (group D), since the effective mAs had to be increased in the corticomedullary phase to maintain image quality. In 2008, as tube current modulation in the x-, y-, and z-axis was introduced (CARE Dose4D), the mean effective dose was reduced to 11.7/8.8 (F/M) mSv (group E). Conclusion: This study shows that the individual mean effective dose to patients undergoing CT urography has decreased by 60%, from 29.9/22.5 (F/M) mSv in 1997 to 11.7/8.8 (F/M) mSv in 2008.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3