Evaluation of a wavelet‐based computer‐assisted detection system for identifying microcalcifications in digital full‐field mammography

Author:

Diekmann F.1,Diekmann S.1,Bollow M.1,Hermann K. G.1,Richter K.1,Heinlein P.1,Schneider W.1,Hamm B.1

Affiliation:

1. Department of Radiology, Humboldt University Berlin, Charité, Berlin, Germany; Image Diagnost, GmbH, Neufahrn/Munich, Germany

Abstract

Purpose: To evaluate a new wavelet‐based computer‐assisted detection (CAD) system for detecting and enhancing microcalcifications. Material and Methods: A total of 280 mammograms acquired by full‐field digital mammography (Senographe 2000D; G.E. Medical Systems Milwaukee, Wisc., USA) were analyzed with and without a new wavelet‐based CAD system for detecting and enhancing microcalcifications. The mammograms comprised roughly equal numbers of cases from each of the BIRADS (Breast Imaging, Reporting and Data System, according to the American College of Roentgenology) categories 1–5. Histologic confirmation was available for all of the 180 cases assigned BIRADS categories 3–5. Four readers interpreted all 280 images for suspicious microcalcifications using a scale of 1–5. The readers alternately assessed 5 images with and 5 without CAD. In a second reading immediately following the first, the readers had to reassess the 280 mammograms. The images that had already been interpreted without CAD were now presented with CAD and vice versa. The images were interpreted as soft copies on a diagnostic mammography workstation (Image Diagnost GmbH, Neufahrn/Munich, Germany). All images interpreted with CAD were presented with enhancement of microcalcifications by wavelet algorithms and prompting of microcalcifications. ROC (receiver operating characteristic) analyses were performed, and image interpretation time with and without CAD was measured. Results: The overall time for interpretation required by all 4 readers together was 483 min with CAD compared to 580 min without CAD. ROC analysis revealed no significant advantage of CAD for the individual readers. Readers 3 (0.811/0.817) and 4 (0.799/0.843) had a slightly improved AUC (area under the curve) with CAD. Readers 1 and 2 had a slightly lower AUC with CAD (0.832 versus 0.861 and 0.818 versus 0.849). Conclusion: The CAD system significantly ( P<0.05, t test) speeded up image interpretation with respect to the identification of microcalcifications, while the diagnostic quality remained almost identical under the study conditions.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. A comparison of computer-assisted detection (CAD) programs for the identification of colorectal polyps: performance and sensitivity analysis, current limitations and practical tips for radiologists;Clinical Radiology;2018-06

2. Human visual system based unsharp masking for enhancement of mammographic images;Journal of Computational Science;2017-07

3. Non-linear polynomial filters for edge enhancement of mammogram lesions;Computer Methods and Programs in Biomedicine;2016-06

4. Improved Non-Linear Polynomial Filters for Contrast Enhancement of Breast Tumors;Proceedings of First International Conference on Information and Communication Technology for Intelligent Systems: Volume 2;2016

5. Breast Tomosynthesis;Seminars in Ultrasound, CT and MRI;2011-08