Assessment of left ventricular function and mass in patients undergoing computed tomography (CT) coronary angiography using 64-detector-row CT: comparison to magnetic resonance imaging

Author:

Schlosser T.1,Mohrs O. K.1,Magedanz A.1,Voigtländer T.1,Schmermund A.1,Barkhausen J.1

Affiliation:

1. Department of Diagnostic and Interventional Radiology, University of Essen, Germany; Department of Cardiovascular Imaging at Alice-Hospital, Darmstadt, Germany

Abstract

Purpose: To quantify left ventricular function and mass derived from retrospectively ECG-gated 64-detector-row computed tomography coronary angiography data sets in comparison to cine magnetic resonance (MR) imaging as the reference standard. We hypothesized that the administration of beta-blockers prior to multidetector computed tomography (MDCT) coronary angiography has a significant impact on left ventricular functional parameters. Material and Methods: Multiplanar reformations in the short-axis orientation were calculated from axial contrast-enhanced CT images in 21 patients (16 male, five female; age range 41–75 years, mean 64.3±6.8 years) referred for CT coronary angiography. Patients whose heart rates exceeded 60 bpm received 5 mg bisoprolol orally 1 hour before the MDCT examination. In case of insufficient heart-rate reduction, up to four vials (20 mg) of metoprolol were injected intravenously. The end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), cardiac output (CO), and left ventricular mass (LVM) of the reformatted images were analyzed compared to volumetric measurements based on continuous short-axis steady-state free-precession cine MR sequences (TR 3 ms, TE 1.5 ms, FA 60°). Results: On average, each patient received 15.5 mg metoprolol (range 0–20 mg) and 3.85 mg bisoprolol (range 0–5 mg). The mean heart rate was 56±5 bpm during CT and 73±9 bpm during MRI examination. This difference was statistically significant ( P<0.05). Mean EDV and ESV measured on MDCT were significantly higher compared to MR (MDCT vs. MR: EDV 164.2±52.5 vs. 144.2±46.7 ml, ESV 77.3±46.6 vs. 63.8±47.3 ml; P<0.05). Mean EF and CO derived from MDCT images were significantly lower compared to MR (MDCT vs. MR: EF 55.4±11.8 vs. 59.3±15.4%, CO 4822±779 vs. 5755±1267 ml; P<0.05). Mean SV and LVM were not significantly different between both methods (MDCT vs. MR: SV 86.8±18.1 vs. 80.3±15.6 ml, P = 0.44; LVM 132.4±42.5 vs. 138.7±39.1 g, P = 0.31). Conclusion: Left ventricular volumes assessed by the newest-generation MDCT scanners are significantly higher compared with MRI, whereas ejection fraction and cardiac output are significantly lower in MDCT. This appears to be a result of the frequent application of beta-blockers prior to MDCT examinations.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3