High‐resolution contrast‐enhanced magnetic resonance angiography of the carotid arteries using fluoroscopic monitoring of contrast arrival: diagnostic accuracy and interobserver variability

Author:

Butz B.1,Dorenbeck U.1,Borisch I.1,Zorger N.1,Lenhart M.1,Feuerbach S.1,Link J.1

Affiliation:

1. Department of Radiology, University of Regensburg Hospital, Regensburg, Germany; Department of Neuroradiology, University of Homburg Hospital, Homburg, Germany; Department of Radiology, Spitalregion St. Gallen, St. Gallen, Switzerland

Abstract

Purpose: To evaluate the diagnostic accuracy of high‐resolution contrast‐enhanced magnetic resonance angiography (CE‐MRA) of the supra‐aortic arteries using the CareBolus technique. Digital subtraction angiography was the standard of reference. Material and Methods: Fifty consecutive patients with suspected internal carotid artery stenosis underwent CE‐MRA and digital subtraction angiography. CE‐MRA was performed on a 1.5‐T superconducting scanner with the CareBolus technique. CareBolus combines a nearly real‐time 2D‐FLASH (fast low angle shot) sequence for fluoroscopic triggering and a high‐resolution 3D‐FLASH with elliptical centric view order for the angiographic pulse sequence (6.0/2.16 ms [TR/TE], 30° flip angle, 30.98 s acquisition time, 0.88 mm effective (interpolated) partition thickness and a 160×512 matrix). Intra‐arterial digital subtraction angiography and CE‐MRA studies were evaluated independently by four blinded readers. Internal carotid artery stenoses were graded according to the NASCET criteria. Results: CE‐MRA had an accuracy of 92.53%, a sensitivity of 95.64%, and a specificity of 90.39% for the identification of carotid artery stenoses ≥70% (grade 3). Image quality for suppression of stationary tissue and venous contrast was good, but was reduced in five cases due to patient motion. Conclusion: The CareBolus technique is a useful non‐invasive method for high‐resolution imaging of the supra‐aortic vessels because of its easy application and high sensitivity and specificity. Limitations can occur in non‐compliant patients due to motion artifacts during the measurement time.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3