Value of sonographically guided needle sampling of cystic versus solid components in the diagnosis of complex cystic breast masses

Author:

Lin Wen-Chiung1,Hsu Giu-Cheng1,Yu Cheng-Ping2,Yu Jyh-Cherng3,Lee Hsiu-Nan2,Hsu Hsian-He1,Chang Tsun-Hou1,Chen Tom4,Li Chao-Shiang4,Huang Guo-Shu1

Affiliation:

1. Department of Radiology, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan

2. Department of Pathology, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan

3. Department of Surgery, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan

4. Department of Radiology, Renai Branch, Taipei City Hospital, Taipei, Taiwan

Abstract

Background: The common practice for diagnosis of complex cystic breast masses (CCBM) may be imaging-guided aspiration or biopsy of cystic or solid components. Purpose: To assess the diagnostic value of sonographically guided needle sampling of cystic and solid components for CCBM. Material and Methods: Twenty patients with 20 CCBM underwent sonographically guided fine-needle aspiration biopsy (FNAB) for cystic components, followed by core needle biopsy (CNB) for residual solid components. The diagnostic results of each were evaluated. Excisional biopsy or mastectomy served as a reference standard. Results: Fourteen (70%) masses were malignant. Needle sampling for cystic components of the 14 malignant tumors showed malignancy in one (7%), atypia in four (29%), benign findings in four (29%), and insufficient samples in five (36%). Needle sampling for residual solid components showed malignancy in 11 (79%), atypia in two (14%), and insufficient sample in one (7%). The diagnostic yield of needle sampling of solid components was significantly higher than that of cystic components for malignant CCBM ( P<0.05). Sixteen (80%) of 20 CCBMs showed bloody fine-needle aspirates. There was no significant difference between the rates of bloody aspirates of malignant and benign CCBM (86% vs. 67%, P=0.55). Conclusion: Sonographically guided needle sampling of solid components may help to identify most malignant CCBMs, and the aspirated fluid may be discarded due to low diagnostic value.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3