Magnetic resonance imaging of hyaline cartilage defects at 1.5T and 3.0T: comparison of medium T2‐weighted fast spin echo, T1‐weighted two‐dimensional and three‐dimensional gradient echo pulse sequences

Author:

Fischbach F.1,Bruhn H.1,Unterhauser F.1,Ricke J.1,Wieners G.1,Felix R.1,Weiler A.1,Schröder R. J.1

Affiliation:

1. Department of Radiology and Department of Traumatic and Reconstructive Surgery, Charité, Campus Virchow-Klinikum, Humboldt-University Medical School, Berlin, Germany

Abstract

Purpose: To evaluate and compare the diagnostic accuracy of appropriate magnetic resonance (MR) sequences in the detection of cartilage lesions at 1.5T and 3.0T. Material and Methods: Twelve chondral defects of varying depths, widths, and locations were created in the retropatellar hyaline cartilage in six sheep cadaver limbs. Axial images employing three fat‐suppressed imaging sequences – (1) a T2‐weighted fast spin‐echo (FSE) sequence, (2) a two‐dimensional (2D) and (3) three‐dimensional (3D) gradient‐echo (GE) sequence at 1.5T and 3.0T using an extremity quadrature coil – were evaluated by three experienced radiologists. Statistical analysis of the results consisted of receiver operating characteristics (ROC) and significant testing using the bivariate chi‐square test. In addition, signal‐to‐noise ratios (SNR) and contrast‐to‐noise ratios (CNR) were evaluated with significance testing using the Wilcoxon test. Results: The 3D GE sequence compared favorably with other sequences at 3.0T and 1.5T (Az = 0.88 at 3.0T and Az = 0.85 at 1.5T) missing only one small grade 2 lesion. 2D GE imaging was inferior to 3D imaging at both field strengths ( P<0.05) in general. However, compared to 1.5T, lesion detectability was improved at the higher magnetic field of 3.0T (Az = 0.81 and 0.73 at 3.0T and 1.5T, respectively). FSE images showed significantly inferior sensitivity and less anatomical detail compared to the GE sequences at both field strengths (Az = 0.64 and 0.72 at 3.0T and 1.5T, respectively; P<0.05). However, compared to 1.5T, lesion detectability SNR and CNR values were superior in all sequences tested at 3.0T. Conclusion: MRI at 3.0T improves SNR and CNR significantly in the most common sequences for cartilage MRI, resulting in an improvement in chondral lesion detection. GE imaging therefore allows resolution to be increased in an acceptable time manner for patient comfort, and the 3D GE fat‐suppressed sequence at 3.0T appears to be best suited for cartilage imaging in a clinical setting.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3