The use of Versius CMR for pelvic surgery: a multicentric analysis of surgical setup and early outcomes

Author:

Sighinolfi Maria ChiaraORCID,De Maria Maurizio,Meneghetti Iacopo,Felline Mauro,Ceretti Andrea Pisani,Mosillo Luca,Catalano Chiara,Morandi Alessandro,Calcagnile Tommaso,Panio Enrico,Sangalli Mattia,Turri Filippo,Terzoni Stefano,Assumma Simone,Sarchi Luca,Afonina Margarita,Marconi Annamaria,Bianchi Paolo Pietro,Micali Salvatore,Rocco Bernardo,Gaia Giorgia

Abstract

Abstract Introduction Versius CMR is a novel robotic system characterized by an open surgical console and independent bedside units. The system has potentials of flexibility and versatility, and has been used in urological, gynecological, and general surgical procedure. The aim is to depict a comprehensive analysis of the Versius system for pelvic surgery. Methods This is a study involving two Institutions, ASST Santi Paolo and Carlo, Milan, and Apuane Hospital, Massa, Italy. All interventions performed in the pelvic area with the Versius were included. Data about indications, intra-, and post-operative course were prospectively collected and analyzed. Results A total of 171 interventions were performed with the Versius. Forty-two of them involved pelvic procedures. Twenty-two had an oncological indication (localized prostate cancer), the remaining had a non-oncological or functional purpose. The mostly performed pelvic procedure was radical prostatectomy (22) followed by annexectomy (9). No intra-operative complication nor conversion to other approaches occurred. A Clavien II complication and one Clavien IIIb were reported. Malfunctioning/alarms requiring a power cycle of the system occurred in 2 different cases. An adjustment in trocar placement according to patients’ height was required in 2 patients undergoing prostatectomy, in which the trocar was moved caudally. In two cases, a pelvic prolapse was repaired concomitant with other gynecological procedures. Conclusions Pelvic surgery with the Versius is feasible without major complications; either dissection and reconstructive steps could be accomplished, provided a proper OR setup and trocar placement are pursued. Versius can be easily adopted by surgeons of different disciplines and backgrounds; a further multi-specialty implementation is presumed and long-term oncological and functional outcomes are awaited.

Funder

Università degli Studi di Milano

Publisher

Springer Science and Business Media LLC

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3