Speckle tracking derived strain in neonates: planes, layers and drift

Author:

Khan UmaelORCID,Omdal Tom R.,Matre Knut,Greve Gottfried

Abstract

AbstractThe aims of this study was to assess the effect of using a four chamber versus a three plane model on speckle tracking derived global longitudinal strain, the effects of drift compensation, the effect of assessing strain in different layers and finally the interplay between these aspects for the assessment of strain in neonates. Speckle tracking derived longitudinal strain was obtained from 22 healthy neonates. ANOVA, Bland–Altman analyses, coefficients of variation and assessment of intraclass correlation coefficients were conducted to assess the effect of the abovementioned aspects as well as assess both inter-observer and intra-observer variability. Neither the use of the three plane model versus the four chamber model nor the use of drift compensation had a substantial effect on global longitudinal strain (less than 1%, depending on which layer was being assessed). A gradient was seen with increasing strain from the epicardial to endocardial layers, similar to what is seen in older subjects. Finally, drift compensation introduced more discrepancy in segmental strain values compared to global longitudinal strain. Global longitudinal strain in healthy neonates remains reasonably consistent regardless of whether the three plane or four chamber model is used and whether drift compensation is applied. Its value increases when one moves from the endocardial to the epicardial layer. Finally, drift compensation introduces more discrepancy for regional measures of longitudinal strain compared to global longitudinal strain.

Funder

Bergen Heart Foundation University of Bergen

University of Bergen

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

Reference35 articles.

1. Leitman M, Lysyansky P, Sidenko S, Shir V, Peleg E, Binenbaum M, Kaluski E, Krakover R, Vered Z (2004) Two-dimensional strain-a novel software for real-time quantitative echocardiographic assessment of myocardial function. J Am Soc Echocardiogr 17(10):1021–1029. https://doi.org/10.1016/j.echo.2004.06.019

2. Lang RM, Badano LP, Mor-Avi V, Afilalo J, Armstrong A, Ernande L, Flachskampf FA, Foster E, Goldstein SA, Kuznetsova T, Lancellotti P, Muraru D, Picard MH, Rietzschel ER, Rudski L, Spencer KT, Tsang W, Voigt J-U (2015) Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr 28(1):1-39.e14. https://doi.org/10.1016/j.echo.2014.10.003

3. Nestaas E, Stoylen A, Brunvand L, Fugelseth D (2011) Longitudinal strain and strain rate by tissue Doppler are more sensitive indices than fractional shortening for assessing the reduced myocardial function in asphyxiated neonates. Cardiol Young 21(1):1–7. https://doi.org/10.1017/S1047951109991314

4. Al-Biltagi M, Tolba OARE, Rowisha MA, Mahfouz AE-S, Elewa MA (2015) Speckle tracking and myocardial tissue imaging in infant of diabetic mother with gestational and pregestational diabetes. Pediatr Cardiol 36(2):445–453. https://doi.org/10.1007/s00246-014-1033-0

5. El-Khuffash A, Schubert U, Levy PT, Nestaas E, de Boode WP, Austin T, Bohlin K, Bravo MC, Breatnach CR, Breindahl M, Dempsey E, Groves AM, Gupta S, Horsberg Eriksen B, McNamara PJ, Molnar Z, Rogerson SR, Roehr CC, Savoia M, Schwarz CE, Sehgal A, Singh Y, Slieker MG, Tissot C, van der Lee R, van Laere D, van Overmeire B, van Wyk L, on behalf of the European Special Interest Group ‘Neonatologist Performed E’ (2018) Deformation imaging and rotational mechanics in neonates: a guide to image acquisition, measurement, interpretation, and reference values. Pediatr Res 84 (1):30–45. https://doi.org/https://doi.org/10.1038/s41390-018-0080-2

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3