Quench Detection of SST-1 TF Coils by Helium Flow and Pressure Measurement

Author:

Sharma A. N.,Pradhan S.,Prasad U.,Varmora P.,Khristi Y.,Doshi K.,Patel D.

Publisher

Springer Science and Business Media LLC

Subject

Nuclear Energy and Engineering,Nuclear and High Energy Physics

Reference23 articles.

1. S. Pradhan, SST-1 mission team status of SST-1 refurbishment. J. Plasma Fusion. Res. Ser. 9, 650–657 (2010)

2. S. Pradhan et al., Superconducting cable-in-conduit-conductor for SST-1 magnets. In 2nd IAEA Technical Committee Meeting on Steady State Operation of Magnetic Fusion Devices, Fukuoka, Japan (1999), 2, p. 482

3. V.L. Tanna et al., Recent progress and development of cryogenics system towards the refurbishment of SST-1. In 24th International Cryogenic Engineering Conference and International Cryogenic Materials Conference 2012, Fukuoka, Japan, 01/2013

4. S. Das et al., Supercritical helium flow requirement and cooling scheme for SST-1 SCMS. In Proceeding ICEC 18, Mumbai, 2000 pp. 443–446

5. A. Rivetti, G. Martini, G. Birello, LHe venturi flowmeters: practical design criteria and calibration method. Cryogenics 34, 449–452 (1994)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Supercritical helium expansivity effects on magnet protection systems;IOP Conference Series: Materials Science and Engineering;2020-03-01

2. Instrumentation for status monitoring and protection of SST-1 superconducting magnets;Fusion Engineering and Design;2016-11

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com