The effect of individual drilling sleeves on the precision of coronectomy tooth sections. An in vitro 3D-printed jaw model experiment

Author:

Pacheco Ana,Soós Balázs,Lempel Edina,Simon Imre,Maróti Péter,Möhlhenrich Stephan Christian,Szalma József

Abstract

Abstract Objectives The aim of this in vitro study was to evaluate the effect of a 3D-printed drill sleeve (DS) on the precision and duration of coronectomy sections. Materials and methods Thirty-six trainees and oral surgeons performed 72 coronectomy cuts in a 3D-printed, entirely symmetric mandible model. Coronectomy was performed freehand (FH) on one side and with a DS on the other side. The occurrence of “too superficial” (≥ 4 mm unprepared lingual tooth tissue) and “too deep” (drilling ≥ 1 mm deeper as tooth contour) cuts and sectioning times were registered. Results In 7 cases, the sections were “too deep” with FH, while none with DS (OR: 18.56; 95%CI: 1.02–338.5; p = 0.048). The deviation between virtually planned and real cut depths was significantly greater in the FH group (1.91 ± 1.62 mm) than in DS group (1.21 ± 0.72 mm) (p < 0.001). A total of 18 “too superficial” buccolingual sections occurred with FH, while 8 cases with DS (OR: 3.50; 95%CI: 1.26–9.72; p = 0.016). Suboptimal sections did not correlate with experience (p = 0.983; p = 0.697). Shortest, suboptimal drillings were most frequently seen distolingually (OR: 6.76; 95% CI: 1.57–29.07; p = 0.01). In the inexperienced group, sectioning time was significantly longer with FH (158.95 ± 125.61 s vs. 106.92 ± 100.79 s; p = 0.038). Conclusions The DS effectively reduced tooth sectioning times by less experienced colleagues. Independently from the level of experience, the use of DS obviated the need for any preparation outside the lingual tooth contour and significantly decreased the occurrence of “too superficial” cuts, leaving thinner unprepared residual tooth tissue lingually. Clinical relevance Coronectomy sections may result in lingual hard and soft tissue injury with the possibility of damaging the lingual nerve. The precision of the buccolingual depth-control can be improved, while surgical time can be reduced when applying a drilling sleeve.

Funder

Magyar Tudományos Akadémia

Nemzeti Kutatási Fejlesztési és Innovációs Hivatal

Általános Orvostudományi Kar, Pécsi Tudományegyetem

University of Pécs

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3