Cleansing efficacy of an auto-cleaning electronic toothbrushing device: a randomized-controlled crossover pilot study

Author:

Schnabl Dagmar,Wiesmüller Vera,Hönlinger Vera,Wimmer Simon,Bruckmoser Emanuel,Kapferer-Seebacher InesORCID

Abstract

Abstract Objectives To compare the cleansing efficacy of a representative “ten seconds” auto-cleaning device with that of uninstructed manual toothbrushing in a pilot study. Materials and methods Twenty periodontally healthy probands refrained from oral hygiene for 3 days. Baseline full-mouth plaque scores (Rustogi Modified Navy Plaque Index, RMNPI) were assessed. After randomization, probands cleaned their teeth either with the auto-cleaning test device according to the manufacturer’s protocol or with a manual toothbrush. Plaque reduction was assessed by two aligned blinded investigators. After a 2-week recovery, the clinical investigation was repeated in a crossover design. The brushing pattern of the auto-cleaning device was analyzed in probands’ casts. Results Full-mouth plaque reduction was 11.37 ± 3.70% for the auto-cleaning device and 31.39 ± 5.27% for manual toothbrushing (p < 0.0001). The investigation of the auto-cleaning device’s brushing pattern in dental casts revealed a positive relationship of bristle rows in contact with tooth surfaces and the cleansing efficacy in the respective areas. A maximum of 2/4 bristle rows were in contact with the tooth surfaces; in some areas, the bristles had no contact to the teeth. Conclusions Uninstructed manual toothbrushing is superior to auto-cleaning. The alignment and density of the auto-cleaning device’s bristle rows need to be improved, and assorted sizes would be necessary to cover different jaw shapes. Clinical relevance The auto-cleaning device has been developed to accommodate individuals with poor dexterity or compliance. To date, it is unable to provide sufficient plaque reduction due to an inappropriate bristle alignment and poor fit with diverse dental arches.

Funder

University of Innsbruck and Medical University of Innsbruck

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Uses and applications of the manual versus electronic toothbrush: A literature review;Journal of International Oral Health;2023

2. Cleansing efficacy of an auto-cleaning toothbrushing device with nylon bristles: a randomized-controlled pilot study;Clinical Oral Investigations;2022-10-22

3. Correcto cepillado dental en niños;Revista Científica Arbitrada en Investigaciones de la Salud GESTAR;2021-01-11

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司