Abstract
Abstract
Objectives
To evaluate the dimensional accuracy of impressions taken by use of disposable stock plastic trays and to compare performance with that of metal trays.
Materials and methods
From a metallic model incorporating three precision balls and three abutment teeth, one-step dual-phase polyether (PE) and vinyl polysiloxane (VPS) impressions were taken using either metal or disposable plastic trays (n = 10 for each of the resulting four test groups). Respective plaster cast scans were aligned with the reference dataset to evaluate global (distance and angle deviations) and local (trueness and precision) accuracy. Analyses of variance (ANOVA) were conducted to determine group differences.
Results
For all impression tray and material combinations, global accuracy was good (mean distance changes < 100 μm) with greatest deviations being observed for distances exceeding one quadrant of the dental arch. In general, distances measured in the plaster casts were too short. Only VPS impressions with plastic trays showed a different behavior with a large percentage of cross-arch distances exceeding the reference value. Mean local accuracy ranged between 6 and 14 μm (trueness), and 6 and 16 μm (precision). On abutment tooth level, metal trays were associated with a significantly better precision (p = 0.015).
Conclusions
The observed distortions of the studied impression trays and materials are small and should enable satisfying clinical impression-taking.
Clinical relevance
Cleaning and processing of metal trays before re-use are time-consuming. Especially for patients’ management with single crowns and small fixed dental prostheses, disposable plastic trays can be a viable and cost-effective alternative.
Funder
Medizinische Fakultät Heidelberg der Universität Heidelberg
Publisher
Springer Science and Business Media LLC
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献