Author:
Hossain Md. Biplob,Tasnim Tamanna,Abdulrazak Lway F.,Rana Md. Masud,Islam Md. Rabiul
Abstract
Abstract
In this paper, a Kretschmann configuration based surface plasmon resonance (SPR) sensor is numerically designed using graphene-MoS2 hybrid structure TiO2-SiO2 nano particles for formalin detection. In this design, the observations of SPR angle versus minimum reflectance and SPR frequency (FSPR) versus maximum transmittance (Tmax) are considered. The chitosan is used as probe legend to perform reaction with the formalin (40% formaldehyde) which acts as target legend. In this paper, both graphene and MoS2 are used as biomolecular acknowledgment element (BAE) and TiO2 as well as SiO2 bilayers is used to improve the sensitivity of the sensor. The numerical results show that the variation of FSPR and SPR angles for inappropriate sensing of formalin is quite insignificant which confirms the absence of formalin. On the other hand, these variations for appropriate sensing are considerably significant that confirm the presence of formalin. At the end of this article, the variation of sensitivity of the proposed biosensor is measured in corresponding to the increment of a refractive index with a refractive index step 0.01 refractive index unit (RIU). In inclusion of TiO2-SiO2 bilayers with graphene-MoS2, a maximum sensitivity of 85.375% is numerically calculated.
Publisher
Springer Science and Business Media LLC
Subject
Atomic and Molecular Physics, and Optics,Electronic, Optical and Magnetic Materials
Reference56 articles.
1. M. B. Hossain, M. Hassan, L. F. Abdulrazak, M. M. Rana, M. M. Islam, and M. S. Rahman, “Graphene-MoS2-Au-TiO2-SiO2 hybrid SPR biosensor for formalin detection: numerical analysis and development,” Advanced Materials Letters, 2019, 10(9): 656–662.
2. M. B. Hossain, M. M. Rana, L. F. Abdulrazak, S. Mitra, and M. Rahman, “Design and analysis of graphene-MoS2 hybrid layer based SPR biosensor with TiO2-SiO2 nano film for formalin detection: numerical approach”, Optical and Quantum Electronics, 2019, 51(6): 195–207.
3. A. S. Sebaei, A. M. Gomaa, A. A. El-Zwahry, and E. A. Emara, “Graphene-MoS2-Au-TiO2-SiO2 hybrid SPR biosensor: a new window for formalin detection,” International Journal of Analytical Chemistry, vol. 2018, Article ID 2757941, 2018.
4. N. Noordiana, A. B. Fatimah, and Y. C. Farhana, “Formaldehyde content and quality characteristics of selected fish and sea food from wet markets,” International Food Research Journal, 2011, 18(1): 125–136.
5. T. S. Yeh, T. C. Lin, C. C. Chen, and H. M. Wen, “Analysis of free and bound formaldehyde in squid and squid products by gas chromatography-mass spectrometry,” Journal of Food and Drug Analysis, 2013, 21(2): 190–197.
Cited by
23 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献