Abstract
Abstract
Background
Purpose was to correlate flexor pollicis longus tendon (FPL) attrition using Ultrasonography with plate position on radiographs following volar locked compression plate fixation (LCP) in patients who have undergone pronator quadratus (PQ) repair for distal radius fractures.
Methods
Status of flexor pollicis longus tendon was analyzed by ultrasonography in patients who underwent volar locked compression plating with pronator quadratus repair at a minimum of one year follow up. Soong’s criteria was used to assess the plate position and then correlated the ultrasonography findings of flexor pollicis longus.
Results
There were 33 patients included in our study, of which 15 belonged to Soong’s grade zero, 10 were grade one and eight were grade two. Flexor pollicis longus attrition was noted in all cases with grade two plating.
Conclusion
Pronator quadratus repair may not prevent attritional changes in higher grades of Soong’s, hence follow up may be required in these patients to identify attritional changes and early implant removal to prevent complications.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine
Reference20 articles.
1. Rick, T., & Asif, M. I. (2013). Prospective evaluation of pronator quadratus repair following volar plate fixation of distal radius fractures. Journal of Hand Surgery (American Volume), 38, 1678–1684.
2. Marjolein, A. M. M., Monique, M. J. W., Fernande, J. M. E., Niels, W. L. S., & Carel, G. (2017). Repair of the pronator quadratus after volar plate fixation in distal radius fractures: a systematic review. Strategies in Trauma and Limb Reconstruction, 17(12), 181–188.
3. Alison, K., Morgan, S., Joseph, J. S., et al. (2013). Volar plate position and flexor tendon rupture following distal radius fracture fixation. Journal of Hand Surgery (American Volume), 38, 1091–1096.
4. Protopsaltis, T. S., & Ruch, D. S. (2008). Volar approach to distal radius fractures. Journal of Hand Surgery (American Volume), 33, 958–965.
5. ChirpazCerbat, J. M., Ruatti, S., Houillon, C., & Ionescu, S. (2008). Dorsally displaced distal radius fractures treated by fixed-angle volar plating: grip and pronosupination strength recovery. A prospective study. Orthopaedics & Traumatology Surgery & Research, 97, 465–470.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献