Abstract
Abstract
Purpose
Detecting malignant peripheral nerve sheath tumors (MPNSTs) remains difficult. 18F-FDG PET-CT has been shown helpful, but ideal threshold values of semi-quantitative markers remain unclear, partially because of variation among scanners. Using EU-certified scanners diagnostic accuracy of ideal and commonly used 18F-FDG PET-CT thresholds were investigated and differences between adult and pediatric lesions were evaluated.
Methods
A retrospective cohort study was performed including patients from two hospitals with a clinical or radiological suspicion of MPNST between 2013 and 2019. Several markers were studied for ideal threshold values and differences among adults and children. A diagnostic algorithm was subsequently developed.
Results
Sixty patients were included (10 MPNSTs). Ideal threshold values were 5.8 for SUVmax (sensitivity 0.70, specificity 0.92), 5.0 for SUVpeak (sensitivity 0.70, specificity 0.97), 1.7 for TLmax (sensitivity 0.90, specificity 0.86), and 2.3 for TLmean (sensitivity 0.90, specificity 0.79). The standard TLmean threshold value of 2.0 yielded a sensitivity of 0.90 and specificity of 0.74, while the standard SUVmax threshold value of 3.5 yielded a sensitivity of 0.80 and specificity of 0.63. SUVmax and adjusted SUV for lean body mass (SUL) were lower in children, but tumor-to-liver ratios were similar in adult and pediatric lesions. Using TLmean > 2.0 or TLmean < 2.0 and SUVmax > 3.5, a sensitivity and specificity of 1.00 and 0.63 can be achieved.
Conclusion
18F-FDG PET-CT offers adequate accuracy to detect MPNSTs. SUV values in pediatric MPNSTs may be lower, but tumor-to-liver ratios are not. By combining TLmean and SUVmax values, a 100% sensitivity can be achieved with acceptable specificity.
Publisher
Springer Science and Business Media LLC
Subject
Cancer Research,Neurology (clinical),Neurology,Oncology
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献