Assessing the efficacy of saline flush in frequency-domain optical coherence tomography for intracoronary imaging

Author:

Kimura MasahiroORCID,Takeda Teruki,Tsujino Yasushi,Matsumoto Yuichi,Yamaji Masayuki,Sakaguchi Tomoko,Maeda Keiko,Mabuchi Hiroshi,Murakami Tomoyuki

Abstract

Abstract Background The increased amount of contrast media in frequency-domain optical coherence tomography (FD-OCT) imaging during percutaneous coronary intervention (PCI) has raised potential concerns regarding impairment of renal function. Objectives This study aimed to evaluate the effectiveness of heparinized saline flush in FD-OCT-guided PCI and identify clinical factors contributing to optimal image quality. Methods We retrospectively collected 100 lesions from 90 consecutive patients, and a total of 200 pullbacks were analyzed for the initial and final evaluation in which saline was used as the flushing medium. Results The study population had a mean age of 73, with 52% having chronic kidney disease (CKD). The median amount of contrast used was 28 ml, and no complications were observed associated with saline flush OCT. Imaging quality was then categorized as excellent, good, or unacceptable. Among the total runs, 87% demonstrated clinically acceptable image quality, with 66.5% classified as excellent images and 20.5% classified as good images. Independent predictors of excellent images included lumen area stenosis ≥ 70% (adjusted odds ratio [OR] 2.37, 95% confidence interval [CI] 1.02–5.47, P = 0.044), and the use of intensive flushing (adjusted OR 2.06, 95% CI 1.11–3.86, P = 0.023) defined as a deep engagement of guiding catheter (GC) or a selective insertion of guide extension catheter (GE). Intensive flushing was performed in 60% of the total pullbacks, and it was particularly effective in improving image quality in the left coronary artery (LCA). Conclusion The use of saline flush during FD-OCT imaging was safe and feasible, which had a benefit in renal protection with adequate imaging quality.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine

Reference27 articles.

1. Tearney GJ, Regar E, Akasaka T, Adriaenssens T, Barlis P, Bezerra HG, Bouma B, Bruining N, Cho JM, Chowdhary S, Costa MA, de Silva R, Dijkstra J, Di Mario C, Dudek D, Falk E, Feldman MD, Fitzgerald P, Garcia-Garcia HM, Gonzalo N, Granada JF, Guagliumi G, Holm NR, Honda Y, Ikeno F, Kawasaki M, Kochman J, Koltowski L, Kubo T, Kume T, Kyono H, Lam CC, Lamouche G, Lee DP, Leon MB, Maehara A, Manfrini O, Mintz GS, Mizuno K, Morel MA, Nadkarni S, Okura H, Otake H, Pietrasik A, Prati F, Räber L, Radu MD, Rieber J, Riga M, Rollins A, Rosenberg M, Sirbu V, Serruys PW, Shimada K, Shinke T, Shite J, Siegel E, Sonoda S, Suter M, Takarada S, Tanaka A, Terashima M, Thim T, Uemura S, Ughi GJ, van Beusekom HM, van der Steen AF, van Es GA, van Soest G, Virmani R, Waxman S, Weissman NJ, Weisz G (2012) Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation. J Am Coll Cardiol 59(12):1058–1072

2. Suter MJ, Nadkarni SK, Weisz G, Tanaka A, Jaffer FA, Bouma BE, Tearney GJ (2011) Intravascular optical imaging technology for investigating the coronary artery. JACC Cardiovasc Imaging 4(9):1022–1039

3. Prati F, Regar E, Mintz GS, Arbustini E, Di Mario C, Jang IK, Akasaka T, Costa M, Guagliumi G, Grube E, Ozaki Y, Pinto F, Serruys PW (2010) Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J 31(4):401–415

4. Prati F, Guagliumi G, Mintz GS, Costa M, Regar E, Akasaka T, Barlis P, Tearney GJ, Jang IK, Arbustini E, Bezerra HG, Ozaki Y, Bruining N, Dudek D, Radu M, Erglis A, Motreff P, Alfonso F, Toutouzas K, Gonzalo N, Tamburino C, Adriaenssens T, Pinto F, Serruys PW, Di Mario C (2012) Expert review document part 2: methodology, terminology and clinical applications of optical coherence tomography for the assessment of interventional procedures. Eur Heart J 33(20):2513–2520

5. Nishida T, Hiro T, Takayama T, Sudo M, Haruta H, Fukamachi D, Hirayama A, Okumura Y (2021) Clinical significance of microvessels detected by in vivo optical coherence tomography within human atherosclerotic coronary arterial intima: a study with multimodality intravascular imagings. Heart Vessels 36(6):756–765

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3