Simultaneous assessment of myocardial perfusion and adrenergic innervation in patients with heart failure by low-dose dual-isotope CZT SPECT imaging

Author:

Assante Roberta,D’Antonio Adriana,Mannarino Teresa,Nappi Carmela,Gaudieri Valeria,Zampella Emilia,Buongiorno Pietro,Cantoni Valeria,Green Roberta,Frega Nicola,Verberne Hein J.,Petretta Mario,Cuocolo Alberto,Acampa Wanda

Abstract

Abstract Background In patients with heart failure (HF) sequential imaging studies have demonstrated a relationship between myocardial perfusion and adrenergic innervation. We evaluated the feasibility of a simultaneous low-dose dual-isotope 123I/99mTc-acquisition protocol using a cadmium-zinc-telluride (CZT) single-photon emission computed tomography (SPECT) camera. Methods and results Thirty-six patients with HF underwent simultaneous low-dose 123I-metaiodobenzylguanidine (MIBG)/99mTc-sestamibi gated CZT-SPECT cardiac imaging. Perfusion and innervation total defect sizes and perfusion/innervation mismatch size (defined by 123I-MIBG defect size minus 99mTc-sestamibi defect size) were expressed as percentages of the total left ventricular (LV) surface area. LV ejection fraction (EF) significantly correlated with perfusion defect size (P < .005), innervation defect size (P < .005), and early (P < .05) and late (P < .01) 123I-MIBG heart-to-mediastinum (H/M) ratio. In addition, late H/M ratio was independently associated with reduced LVEF (P < .05). Although there was a significant relationship (P < .001) between perfusion and innervation defect size, innervation defect size was larger than perfusion defect size (P < .001). At multivariable linear regression analysis, 123I-MIBG washout rate (WR) correlated with perfusion/innervation mismatch (P < .05). Conclusions In patients with HF, a simultaneous low-dose dual-isotope 123I/99mTc-acquisition protocol is feasible and could have important clinical implications.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3