No differences in outcomes between cemented and uncemented acetabular components after 12–14 years: results from a randomized controlled trial comparing Duraloc with Charnley cups

Author:

Bjørgul Kristian,Novicoff Wendy M.,Andersen S. T.,Brevig K.,Thu F.,Wiig M.,Åhlund O.

Abstract

Abstract Background Even though there are multiple studies documenting the outcome of the Charnley low-friction arthroplasty as well as abundant studies on uncemented arthroplasties, there is a dearth of comparative studies of the uncemented acetabular component and a cemented component. In this study we aimed to document the long-term clinical and radiographic outcome as well as component survival in a randomized controlled trial. Materials and methods Two hundred fifteen patients (240 hips) were randomly allocated to receive a cemented Charnley cup or uncemented Duraloc 1200 cup. All patients received cemented Charnley stems and were evaluated clinically and radiographically after 6 months, and 2, 5, and 10 years. Results Harris Hip Scores improved from 48.3 [95% confidence interval (CI) 45.0–51.6] to 90.2 [95% CI 87.9–92.6] in the Charnley group and from 49.3 [95% CI 86.9–91.3] in the Duraloc group at 6 months. After 10 years, the Charnley group’s Harris Hip Score was 89.8 [95% confidence interval (CI) 87.0–92.6], and the Duraloc group’s score was 87.3 (95% CI 84.1–90.6). In the radiographic analysis after 10 years, there was no statistical difference in the prevalence of radiographic signs of loosening. Nine cups were revised in the Charnley group, and five cups were removed in the Duraloc group. The difference was not statistically significant. There was no statistical difference between the cups when aseptic loosening was the end-point, nor in survival analyses. Conclusions There is no statistically significant difference in clinical or radiological outcome between the Charnley cup and the Duraloc after 10 years, and no difference in implant survival after 12–14 years. The uncemented Duraloc cup is as good as the cemented Charnley cup after 10 years.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3