Abstract
AbstractBy using microorganisms and the microalgae Chlorella vulgaris in conjunction with sequencing batch reactors (SBRs), the performance of a wastewater treatment facility was studied. For this purpose, the effect of pH, temperature, $${\mathrm{COD}}_{\mathrm{inlet}}$$
COD
inlet
, and air flowrate on COD removal rate and residual was investigated. A single-factorial optimization method is utilized to optimize the amount of COD removal, and the best result is obtained with a pH of 8, $${\mathrm{COD}}_{\mathrm{inlet}}=600\, \mathrm{mg}/\mathrm{l}$$
COD
inlet
=
600
mg
/
l
, and an airflow rate of 55 l/min. Under optimal conditions, the amount of residual COD in the effluent reached 36 $$\mathrm{mg}/\mathrm{l}$$
mg
/
l
, showing an augmentation in the efficiency of the desired system. Moreover, empirical correlations are proposed for double-factorial optimization of residual COD and COD removal. Also, a multilayer perceptron artificial neural network is proposed to model the process and predict the residual COD concentration. The useful technique of hyperparameter tuning is utilized to obtain the best result for the predictions. All the effective parameters, including the number of hidden layers, neurons, epochs, and batch size, are adjusted. Data from the experiments agreed well with the artificial neural network modeling results. For this modeling, the values of the correlation coefficient ($${R}^{2}$$
R
2
) and mean absolute error (MAE) were obtained as 0.98 and 2%, respectively.
Publisher
Springer Science and Business Media LLC
Subject
Water Science and Technology
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献