Author:
Zhang Zhenjie,Zeng Chunpin,Zhang Enzhong,Su Qingwei,Li Min,Gong Liang,Geng Fuqiang,Zhang Zhigang
Abstract
AbstractA large amount of pumping in the deep foundation pit will reduce the groundwater level and lead to surface cracking, building settlement, ground collapse and spring water cut-off. And the groundwater recharge is a good control measure. An integrated system of dewatering and recharge for the deep foundation pit is developed, and it is mainly composed of a pumping system, an assembled water tank, a variable frequency pressure system, a cleaning and filtering system, a recharge pressure tank, a recharge well system and a central control system. This system can realize intelligent automatic control according to the monitoring data. It does not require staff to operate on site and can be remotely adjusted by computer or mobile phone. Taking a subway station under construction in Jinan as the background, the single well recharge test and the multiple wells recharge test were carried out. It can be found that with the increase of recharge pressure, the recharge volume gradually increases, but the increasing trend is smaller and smaller. The relationship between the groundwater level and the recharge volume is a logarithmic function. Blindly increasing recharge wells may not improve the overall reinjection volume, and the relationship between the number of recharge wells, the diameter of reinjection pipes and the maximum recharge capacity of the variable frequency pressure system needs to be comprehensively considered.
Funder
City of Springs Industry Leading Talents Support Program
Publisher
Springer Science and Business Media LLC
Subject
Water Science and Technology
Reference21 articles.
1. Guo F, Wang GH, Kan SL et al (2022) Field test study on groundwater recharge of pebble phreatic aquifer in Beijing. Sci Tech & Eng 20(32):13379–13385
2. He YW, Yin XT, Li D et al (2008) Study on dewatering and recharging of deep foundation pit by numerical test. Sichuan Building Sci 5:108–112
3. Huang YC, Xu YQ (2014) Numerical simulation analysis of dewatering and recharge process of deep foundation pits. Chin J Geotech Eng 36(S2):299–303
4. Jacob CE (1946) Radial flow in a leaky artesian aquifer. EOS Trans Am Geophys Union 27(2):198–208. https://doi.org/10.1029/TR027i002p00198
5. Li Y, Neuman SP (2007) Flow to a well in a five-layer system with application to the Oxnard Basin. Groundwater 45(6):672–682. https://doi.org/10.1111/j.1745-6584.2007.00357.x
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献