Reconstruction of mechanical leg axis using non-modular cemented hinged prosthesis in complex primary total knee arthroplasty

Author:

Jacob BenjaminORCID,Jacob Nadja,Röhner Eric,Wassilew Georgi,Matziolis Georg,Heinecke Markus

Abstract

Abstract Purpose Modular cementless knee arthroplasty systems are capable of precise reconstruction of the mechanical axis. However, they are considered more susceptible to complications. In contrast, non-modular cemented systems are said to be more forgiving and show good long-term results. The aim of this study was to investigate the resulting leg axis after implantation of a non-modular cemented rotating hinged knee prosthesis. Furthermore, potential risk factors for the occurrence of malalignment and complications should be identified. Methods Between 2005 and 2015, 115 patients could be included in this monocentric retrospective cohort study. All patients underwent primary hinged non-modular cemented total knee arthroplasty. Preoperative and postoperative standardized long radiographs were analysed to determine resulting leg axis. Furthermore, epidemiological and intraoperative data as well as perioperative complications were surveyed. Results Average leg axis was 5.8° varus preoperatively and 0.6° valgus postoperatively. Considering an axis deviation of 3° as the target corridor, 27% of all cases examined were outside the desired range. 21% cases showed a femoral deviation from the target corridor and 15% showed a tibial deviation. There was a significant relationship between the preoperative mLDFA and the mechanical alignment of the femoral component (R = 0.396, p < 0.001) as well as between the preoperative mMPTA and the mechanical alignment of the tibial component (R = 0.187, p = 0.045). The mean operative duration was 96 min. No periprosthetic fractures were observed within the study cohort. Conclusion The main result of the present work is that a non-modular cemented rotating hinged knee arthroplasty system can reconstruct the mechanical leg axis precisely and comparable to modular cementless and unconstrained total knee prostheses. Component malalignment is primarily dependent upon extraarticular deformity preoperatively. Periprosthetic fracture rates and duration of surgery were lower compared with current literature. Level of evidence Level III: Retrospective cohort study.

Publisher

Springer Science and Business Media LLC

Reference31 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3