Author:
Leiss Franziska,Götz Julia Sabrina,Meyer Matthias,Maderbacher Günther,Reinhard Jan,Parik Lukas,Grifka Joachim,Greimel Felix
Abstract
Abstract
Background
Femoral component subsidence is a known risk factor for early failure of total hip arthroplasty (THA) using cementless stems. The aim of the study was to compare an enhanced recovery concept with early full weight-bearing rehabilitation and partial weight-bearing on stem subsidence. In addition, the influence of patient-related and anatomical risk factors on subsidence shall be assessed.
Methods
One hundred and fourteen patients underwent primary cementless THA and were retrospectively analyzed. Sixty-three patients had an enhanced recovery rehabilitation with early full weight-bearing and 51 patients had rehabilitation with partial weight-bearing (20 kg) for 6 weeks. Postoperative subsidence was analyzed on standing pelvic anterior–posterior radiographs after 4 weeks and 1 year. Subsidence was measured in mm. Anatomical and prosthetic risk factors (stem size, canal flare index, canal fill ratio as well as BMI and demographic data) were correlated.
Results
Femoral stem subsidence rate was significantly higher for the group with an enhanced recovery concept compared to the group with partial weight-bearing at the first radiological follow up after 4 weeks [2.54 mm (SD ± 1.86) vs. 1.55 mm (SD ± 1.80)] and the second radiological follow up after 1 year [3.43 mm (SD ± 2.24) vs. 1.94 (SD ± 2.16)] (p < 0.001, respectively). Stem angulation > 3° had a significant influence on subsidence. Canal flare index and canal fill ratio showed no significant correlation with subsidence as well as BMI and age.
Conclusion
In the present study, cementless stem subsidence was significantly higher in the group with enhanced recovery rehabilitation compared to partial weight-bearing. Small absolute values and differences were demonstrated and therefore possibly below clinical relevance. Anatomical radiological parameters and anthropometric data did not appear to be risk factors for stem subsidence.
Funder
Universitätsklinikum Regensburg
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,General Medicine,Surgery,Surgery
Reference42 articles.
1. Learmonth ID, Young C, Rorabeck C (2007) The operation of the century: total hip replacement. Lancet (London, England) 370:1508–1519
2. Australian Orthopaedic Association National Joint Replacement Registry (AOANJR) (2018) Hip, knee & shoulder arthroplasty: 2018 Annual Report. AOA; Adelaide, Australia
3. Campbell D, Mercer G, Nilsson KG, Wells V, Field JR, Callary SA (2011) Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study. Int Orthop 35:483–488
4. Al-Najjim M, Khattak U, Sim J, Chambers I (2016) Differences in subsidence rate between alternative designs of a commonly used uncemented femoral stem. J Orthop 13:322–326
5. Selvaratnam V, Shetty V, Sahni V (2015) Subsidence in collarless corail hip replacement. Open Orthop J 9:194–197
Cited by
16 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献