Femoral revision in total hip arthroplasty using a cementless modular stem: clinical and radiological results with a 8-year follow-up

Author:

Spranz David,Skrobek David,Randoll Jannis,Kinkel Stefan,Merle Christian,Walker Tilman,Renkawitz Tobias,Reiner Tobias

Abstract

Abstract Introduction Modular femoral components allow for patient-specific restoration of hip joint geometry and the reconstruction of extensive bone defects in revision total hip arthroplasty (THA); however, potential problems of modular implants such as taper corrosion and the risk of implant fracture continue to be of concern. The aim of the present study was to evaluate the clinical and radiological results of a cementless modular revision stem following revision surgery due to aseptic loosening and periprosthetic fracture and to assess patient-reported outcome measures (PROMs) in these patients at mid-term follow-up. Materials and methods In this study, a consecutive cohort of 75 patients who underwent primary revision THA at our institution using a modular cementless stem design (MRP-TITAN stem) was retrospectively evaluated at a mean follow-up of 7.7 years. Kaplan–Meier survivorship analyses were performed with revision of the femoral component for any reason as the end point. The Harris-Hip Score, the UCLA Activity Score, the Forgotten Joint Score and the SF-12 Score were used for clinical assessment. We used the Wilcoxon signed rank test to compare pre- and postoperative clinical scores. Results Overall stem survival with the endpoint stem re-revision for any reason was 85.4% at a mean follow-up of 7.7 years (range 2.4–14 years). Stem survival was 89.5% in the aseptic loosening group and 78.3% in the periprosthetic fracture group with no statistically significant difference between both groups (p = 0.107). One patient had to be revised due to taper fracture. PROMs improved significantly up to the latest follow-up, and radiographic evaluation showed full osseointegration of all stems in this cohort. Conclusions Revision THA using a modular cementless titanium revision stem demonstrated adequate clinical and radiological results at mid- to long-term follow-up in this cohort. Cementless revision stems are a useful treatment option to restore the anatomy, especially in deformed hips and in complex revision hip arthroplasty. However, there are some significant disadvantages related to an increased risk of mechanical failure such as corrosion/fretting damage and implant fracture. Future high-quality prospective studies with longer follow-up are necessary to confirm the supposed advantages.

Funder

Universitätsklinikum Heidelberg

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司