Retrospective evaluation of radiological and clinical outcomes after surgical treatment of proximal femoral fractures utilizing PFNA and PFNA augmented

Author:

Schneider Friedemann,Oettle Cedric,Runer Armin,Wagner Moritz,Arora Rohit,Lindtner Richard A.ORCID

Abstract

Abstract Introduction The primary aim of this study was to evaluate the clinical and radiological outcomes after surgical treatment of proximal femoral fractures utilizing the Proximal Femoral Nail Antirotation (PFNA), with the main focus on complications and reoperations. The secondary aim was to compare the outcomes of patients with and without cement augmentation of the cephalomedullary nails. Materials and methods All patients with an acute proximal femoral fracture consequently treated with a PFNA between January 2011 and Dezember  2018 were evaluated. Clinical and radiological data were assessed for intra- and postoperative complications, including treatment failure. In addition, intra- and postoperative radiographs were used to determine the position of the implant, and any migration, via Tip-Apex-Distance (TAD) and the caput-collum-diaphyseal angle (CCD). The accuracy of the fracture reduction was rated according to Baumgaertners criteria. Results Two hundred sixty-four consecutive patients (mean age 78.8 ± 12.0; 73.1% female) were included. The predominant OTA/AO fracture classification was 31A1 (153 cases, 58.0%). The average duration of surgery was 63.1 ± 28.0 min and showed no significant differences between PFNA and PFNA with augmentation. The implant positioning was rated as good in 222 cases (84.1%). Two hundred sixty-three patients (99.6%) showed evidence of healing within the time frame of three months postoperatively, one case of delayed union healed after secondary dynamization. During the observational period, 18 patients (6.8%) required a total of 23 additional surgeries. Overall, a lower reoperation rate was observed following the use of the augmentation option (2/86 patients (2.3%) vs. 16/178 patients (9.0%), p = 0.04). In particular, there were no cases of cut-out or cut-through among patients who underwent augmentation as part of osteosynthesis. Conclusions Overall reoperation rate after surgical treatment of proximal femoral fractures utilizing the Proximal Femoral Nail Antirotation (PFNA) was 6.8%, with 23 additional surgeries performed in 18 patients. The usage of the PFNA with augmentation showed equally good implant positioning, excellent healing rates and fewer postoperative complications compared to the PFNA implant alone with a similar overall duration of surgery.

Funder

University of Innsbruck and Medical University of Innsbruck

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3