Poor usability of computer-assisted navigation for hip fracture surgery

Author:

Hestehave Rasmus AbildtrupORCID,Gundtoft Per HviidORCID,Nielsen Christian LindORCID,Brink OleORCID,Rölfing Jan DuedalORCID

Abstract

Abstract Introduction The STRYKER ADAPT computer-assisted navigation system provides intraoperative feedback to the surgeon regarding implant placement of the Gamma3 nail. The usability of the ADAPT system has not been evaluated. The aim of the study was to investigate the perceived usability of the ADAPT system. Materials and methods This was a descriptive study with prospectively collected data. ADAPT was introduced at Aarhus University Hospital in February 2021. Prior to introduction, surgeons at the department attended a general introduction to the system. ADAPT was introduced to the surgical nurses and was on display at the surgical ward at more than one occasion, where personal introduction to the system was possible. After introduction, it was mandatory to use ADAPT when using the Gamma3 nail to treat intertrochanteric femur fractures. After each procedure, primary and an eventual supervisor answered a questionnaire, which encompassed the System Usability Scale (SUS) questionnaire. The SUS is a ten-item questionnaire regarding the perceived usability of a system. SUS scores were translated to adjectives, describing user experience on a 7-point adjective scale (worst imaginable, awful, poor, ok, good, excellent, best imaginable). User acceptability, defined as “not acceptable”, “marginal” or “acceptable”, was also used to interpret the SUS scores. Results ADAPT was used in 50 procedures by 29 different surgeons, with varying skill-level. Median SUS-score after first-time use of ADAPT for all 29 surgeons was 43 (range: 5–60), which translated to “poor” or “not acceptable”. For surgeons who performed ≥ 3 ADAPT-assisted procedures, there were no statistically significant difference in their first to latest SUS-score (median difference: 4.3, p = 0.5). In free text comments ADAPT was positively described as helpful in placement of K-wire and providing educational opportunities for inexperienced surgeons and negatively as inconsistent, slow, time consuming, and causing excessive fluoroscopy. Conclusions Usability and acceptability of ADAPT was rated as “poor” or “not acceptable” by the majority of operating surgeons. ADAPT has not been used at our institution based on these findings. The System Usability Scale may be used in further research exploring usability and acceptability of novel computer-assisted navigation systems for orthopaedic surgery.

Funder

Aarhus University Hospital

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3