Better restoration of joint line obliquity in tibia first restricted kinematic alignment versus mechanical alignment TKA

Author:

Shichman IttaiORCID,Hadad Aidan,Brandstetter Addy S.,Ashkenazi Itay,Warschwaski Yaniv,Gold Aviram,Snir Nimrod

Abstract

Abstract Introduction In total knee arthroplasty (TKA), suboptimal restoration of joint line obliquity (JLO) and joint line height (JLH) may lead to diminished implant longevity, increased risk of complications, and reduced patient reported outcomes. The primary objective of this study is to determine whether restricted kinematic alignment (rKA) leads to improved restoration of JLO and JLH compared to mechanical alignment (MA) in TKA. Materials and Methods This retrospective study assessed patients who underwent single implant design TKA for primary osteoarthritis, either MA with manual instrumentation or rKA assisted with imageless navigation robotic arm TKA. Pre- and post-operative long standing AP X-ray imaging were used to measure JLO formed between the proximal tibial joint line and the floor. JLH was measured as the distance from the femoral articular surface to the adductor tubercle. Results Overall, 200 patients (100 patients in each group) were included. Demographics between the two groups including age, sex, ASA, laterality, and BMI did not significantly differ. Distribution of KL osteoarthritis classification was similar between the groups. For the MA group, pre- to post-operative JLO significantly changed (2.94° vs. 2.31°, p = 0.004). No significant changes were found between pre- and post-operative JLH (40.6 mm vs. 40.6 mm, p = 0.89). For the rKA group, no significant changes were found between pre- and post-operative JLO (2.43° vs. 2.30°, p = 0.57). Additionally, no significant changes were found between pre- and post-operative JLH (41.2 mm vs. 42.4 mm, p = 0.17). Pre- to post-operative JLO alteration was five times higher in the MA group compared to the rKA group, although this comparison between groups did not reach statistical significance (p = 0.09). Conclusion rKA-TKA results in high restoration accuracy of JLO and JLH, and demonstrates less pre- and post-operative JLO alteration compared to MA-TKA. With risen interest in joint line restoration accuracy with kinematic alignment, these findings suggest potential advantages compared to MA. Future investigation is needed to correlate between joint line restoration accuracy achieved by rKA and enhanced implant longevity, reduced risk of post-operative complications, and heightened patient satisfaction.

Funder

Tel Aviv University

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3