Peroneal artery injury potential due to different syndesmosis screw placement options: a simulation study with lower extremity computed tomography angiography

Author:

Aytekin KürşadORCID,Çakır İsmet MiraçORCID,Taşdemir Merve NurORCID,Balta OrhanORCID

Abstract

Abstract Introduction The aim of this study is to assess the risk of peroneal artery injury of hardware placement at the fixation of syndesmotic injuries. Materials and methods The lower extremity computed tomography angiography was used to design the study. The syndesmosis screw placement range was simulated every 0.5 cm, from 0.5 to 5 cm proximal to the ankle joint. The screw axes were drawn as 20°, 30° or individual angle according to the femoral epicondylar axis. The proximity between the screw axis and the peroneal artery was measured in millimeters. Potential peroneal artery injury was noted if the distance between the peroneal artery to the axis of the simulated screw was within the outer shaft radius of the simulated screw. The Pearson chi-square test was used and a p-value < 0.05 was considered significant. Results The potential for injury to the peroneal artery increased as the syndesmosis screw level rose proximally from the ankle joint level or as the diameter of the syndesmosis screw increasds. In terms of syndesmosis screw trajection, the lowest risk of injury was observed with the syndesmosis screw angle of 20°. Simulations with a screw diameter of 3.5 mm exhibited the least potential for peroneal artery injury. Conclusion Thanks to this radiological anatomy simulation study, we believe that we have increased the awareness of the peroneal artery potential in syndesmosis screw application. Each syndesmosis screw placement option may have different potential for injury to the peroneal artery. To decrease the peroneal artery injury potential, we recommend the followings. If individual syndesmosis screw angle trajection can be measured, place the screw 1.5 cm proximal to the ankle joint using a 3.5 mm screw shaft. If not, fix it with 30° trajection regardless of the screw diameter at the same level. If the most important issue is the peroneal artery circulation, use the screw level up to 1 cm proximal to the ankle joint regardless of the screw angle trajection and screw diameter.

Funder

Giresun University

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3