An anteromedial stabilization procedure has the most protective effect on the anterior cruciate ligament in tibial external rotation. A human knee model study

Author:

Blanke FabianORCID,Boljen Matthias,Oehler Nicola,Lutter Christoph,Tischer Thomas,Vogt Stephan

Abstract

Abstract Introduction Anterior cruciate ligament (ACL) reconstruction remains associated with the risk of re-rupture and persisting rotational instability. Additional extraarticular anterolateral stabilization procedures stabilize the tibial internal rotation and lead to lower ACL failure rate and improved knee stability. However, data for additional stabilization of tibial external rotation is lacking and the importance of an anteromedial stabilization procedure is less well evaluated. Aim of this study is to investigate the influence of an extraarticular anteromedial stabilization procedure for the stabilization of the tibial external rotation and protection of the ACL from these rotational forces. Methods Internal and external rotations of the tibia were applied to a finite element (FE) model with anatomical ACL, posterior cruciate ligament (PCL), lateral collateral ligament (LCL), medial collateral ligament (MCL) and intact medial and lateral meniscus. Five additional anatomic structures (Anteromedial stabilization/anteromedial ligament, AML, augmented superficial medial collateral ligament, sMCL, posterior oblique ligament, POL, anterolateral ligament, ALL, and popliteal tendon, PLT) were added to the FE model separately and then combined. The force histories within all structures were measured and determined for each case. Results The anteromedial stabilization or imaginary AML was the main secondary stabilizer of tibial external rotation (90% of overall ACL force reduction). The AML reduced the load on the ACL by 9% in tibial external rotation which could not be achieved by an augmented sMCL (-1%). The AML had no influence in tibial internal rotation (-1%). In the combined measurements with all additional structures (AML, ALL, PLT, POL) the load on the ACL was reduced by 10% in tibial external rotation. Conclusion This study showed that an additional anteromedial stabilization procedure secures the tibial external rotation and has the most protective effect on the ACL during these external rotational forces.

Funder

Universitätsmedizin Rostock

Publisher

Springer Science and Business Media LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3