Abstract
Abstract
Purpose
Polyethylene (PE) wear remains a common reason for revision surgery following total hip arthroplasty (THA). An established treatment method is isolated liner exchange in a well-fixed acetabular cup and entails a known high risk of hip dislocation after revision surgery. The purpose of this retrospective study was to determine the rate of hip dislocation after liner exchange.
Methods
Patients were included if (1) the PE liner was removable, (2) the acetabular shell was stable with acceptable orientation, (3) no osteolysis around the acetabular cup was found and (4) no dislocation of the THA occurred before revision surgery. We reviewed medical histories and performed radiological measurements using Einzel-Bild-Röntgen-Analyse (EBRA) software. EBRA measurements and statistical investigations were performed by two independent investigators.
Results
A total of 82 patients were included in our study. Mean follow-up was six (range: 3.6–9.9) years. In 13 (15.8%) patients THA dislocations occurred at a mean postoperative period of 20.2 (range: 1–44) weeks after revising the PE liner. This is equivalent to an absolute risk increase of 16% after revision surgery, which results in a number needed to harm of 6. This means that every sixth patient with isolated liner exchange can expect to experience dislocation due to wear.
Conclusion
In conclusion, isolated exchange of the polyethylene liner because of wear showed a high risk of dislocation and further cup revision. Our results suggest that the threshold for revising well-fixed components in the case of liner wear should be lowered.
Trial Registration number and date of registration
Number: 20140710-1012 and Date: 2016-03-09.
Funder
University of Innsbruck and Medical University of Innsbruck
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,General Medicine,Surgery,Surgery
Reference44 articles.
1. Petis SM, Kubista B, Hartzler RU, Abdel MP, Berry DJ (2019) Polyethylene liner and femoral head exchange in total hip arthroplasty: factors associated with long-term success and failure. J Bone Joint Surg Am 101:421–428. https://doi.org/10.2106/JBJS.18.00522
2. Adelani MA, Mall NA, Nyazee H, Clohisy JC, Barrack RL, Nunley RM (2014) Revision total hip arthroplasty with retained acetabular component. J Bone Joint Surg Am 96:1015–1020. https://doi.org/10.2106/JBJS.L.01177
3. Oberaigner WLH, Harrasser L, Krismer M, Blauth M (2015) Prothesenregister Tirol. Bericht über die Operationsjahre 2011–2013 und Revisionsstatistik der Operationsjahre 2004–2012. Innsbruck Tirol Kliniken Institut für klinische Epidemiologie
4. Grimberg A JV, Liebs T, Melsheim er O, Steinbrück A (2015) Endoprothesenregister Deutschland: Jahresbericht 2015. EPRD Deutsche Endoprothesenregister gGmbH Berlin
5. Koh KH, Moon YW, Lim SJ, Lee HI, Shim JW, Park YS (2011) Complete acetabular cup revision versus isolated liner exchange for polyethylene wear and osteolysis without loosening in cementless total hip arthroplasty. Arch Orthop Trauma Surg 131:1591–1600. https://doi.org/10.1007/s00402-011-1338-x
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献