Abstract

Abstract Purpose Inter-aural insertion depth difference (IEDD) in bilateral cochlear implant (BiCI) with continuous interleaved sampling (CIS) processing is known to reduce the recognition of speech in noise and spatial release from masking (SRM). However, the independent channel selection in the ‘n-of-m’ sound coding strategy might have a different effect on speech recognition and SRM when compared to the effects of IEDD in CIS-based findings. This study aimed to investigate the effect of bilateral ‘n-of-m’ processing strategy and interaural electrode insertion depth difference on speech recognition in noise and SRM under conditions that simulated bilateral cochlear implant listening. Methods Five young adults with normal hearing sensitivity participated in the study. The target sentences were spatially filtered to originate from 0° and the masker was spatially filtered at 0°, 15°, 37.5°, and 90° using the Oldenburg head-related transfer function database for behind the ear microphone. A 22-channel sine wave vocoder processing based on ‘n-of-m’ processing was applied to the spatialized target-masker mixture, in each ear. The perceptual experiment involved a test of speech recognition in noise under one co-located condition (target and masker at 0°) and three spatially separated conditions (target at 0°, masker at 15°, 37.5°, or 90° to the right ear). Results The results were analyzed using a three-way repeated measure analysis of variance (ANOVA). The effect of interaural insertion depth difference (F (2,8) = 3.145, p = 0.098, ɳ2 = 0.007) and spatial separation between target and masker (F (3,12) = 1.239, p = 0.339, ɳ2 = 0.004) on speech recognition in noise was not significant. Conclusions Speech recognition in noise and SRM were not affected by IEDD ≤ 3 mm. Bilateral ‘n-of-m’ processing resulted in reduced speech recognition in noise and SRM.

Funder

Manipal Academy of Higher Education - Kasturba Medical College, Mangalore

Publisher

Springer Science and Business Media LLC

Subject

General Medicine,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3