Author:
Kouijzer Ilse J. E.,Speijker L. T. D.,Aarntzen E. H. J. G.,Rijnen W. H. C.,Somford M. P.,Maat I.,van Meer M. P. A.,Oever J. Ten,Gisolf E. H.
Abstract
Abstract
Purpose
To assess the likelihood of occult infection in patients with clinically unsuspected orthopedic implants during Staphylococcus aureus bacteremia (SAB).
Methods
In a retrospective study in two Dutch hospitals, we included all patients with SAB between 2013 and 2020 with one or more orthopedic implants in whom [18F]FDG-PET/CT was performed. The primary outcome was the percentage of patients who had an orthopedic implant-related infection by S. aureus. We also compared clinical parameters in patients with clinically suspected and unsuspected implants.
Results
Fifty-five of 191 (29%) orthopedic implants in 118 SAB patients included had clinical signs of infection. Of all 136 unsuspected implants, 5 (3%, all arthroplasties), showed increased [18F]FDG uptake around the prosthesis on [18F]FDG-PET/CT. The clinical course of these patients without clinically overt infection or relapse of bacteremia during follow-up of a median of 48 months (range 0–48), however, argued against prosthetic joint infection.
Conclusion
Although orthopedic implants are evidently a risk factor for metastatic infection during SAB, the absence of clinical symptoms obviate the need of additional investigations or prolonged antibiotic treatment.
Publisher
Springer Science and Business Media LLC
Subject
Infectious Diseases,Microbiology (medical),General Medicine
Cited by
5 articles.
订阅此论文施引文献