A robust motion correction technique for infrared thermography during awake craniotomy

Author:

Iorga MichaelORCID,Tate Matthew C.ORCID,Parrish Todd B.ORCID

Abstract

Abstract Purpose Intraoperative infrared thermography is an emerging technique for image-guided neurosurgery, whereby physiological and pathological processes result in temperature changes over space and time. However, motion during data collection leads to downstream artifacts in thermography analyses. We develop a fast, robust technique for motion estimation and correction as a preprocessing step for brain surface thermography recordings. Methods A motion correction technique for thermography was developed which approximates the deformation field associated with motion as a grid of two-dimensional bilinear splines (Bispline registration), and a regularization function was designed to constrain motion to biomechanically feasible solutions. The performance of the proposed Bispline registration technique was compared to phase correlation, a band-stop filter, demons registration, and the Horn–Schunck and Lucas–Kanade optical flow techniques. Results All methods were analyzed using thermography data from ten patients undergoing awake craniotomy for brain tumor resection, and performance was compared using image quality metrics. The proposed method had the lowest mean-squared error and the highest peak-signal-to-noise ratio of all methods tested and performed slightly worse than phase correlation and Demons registration on the structural similarity index metric (p < 0.01, Wilcoxon signed-rank test). Band-stop filtering and the Lucas–Kanade method were not strong attenuators of motion, while the Horn–Schunck method was well-performing initially but weakened over time. Conclusion Bispline registration had the most consistently strong performance out of all the techniques tested. It is relatively fast for a nonrigid motion correction technique, capable of processing ten frames per second, and could be a viable option for real-time use. Constraining the deformation cost function through regularization and interpolation appears sufficient for fast, monomodal motion correction of thermal data during awake craniotomy.

Funder

National Institute of Neurological Disorders and Stroke

Publisher

Springer Science and Business Media LLC

Subject

Health Informatics,Radiology, Nuclear Medicine and imaging,General Medicine,Surgery,Computer Graphics and Computer-Aided Design,Computer Science Applications,Computer Vision and Pattern Recognition,Biomedical Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3