Decreased radiation exposure using pulsed fluoroscopy and a detachable pedicle marker and probe to place pedicle screws: a comparison to current fluoroscopy techniques and CT navigation

Author:

Marco Rex A. W.,Curry Michael C.,Mujezinovic Faruk,Linton Judith

Abstract

Abstract Study design Quality improvement evaluation with retrospective analysis. Objectives To compare a technique to place pedicle screws (PS) using a novel detachable pedicle marker and probe (DPMP) and pulsed fluoroscopy (PF) vs. conventional technique utilizing PF with standard instruments (SI) and O-arm. Summary of background data Spinal fusion with pedicle screw instrumentation (PSI) is the mainstay in treatment of spinal deformities. Reports suggest that CT navigated (O-arm) PS placement is more accurate than fluoroscopy. However, these studies have not considered the increased radiation exposure associated with CT. Methods Thirty-six patients with spinal deformity had PSI using PF and DPMPs. Accuracy of PS placement and radiation data from 14 dosimeters placed on the patient and around the operating room was analyzed. Results were compared to published data. Results Mean fluoroscopic time was 13.4 s (range 6.0–32.4), and the mean cumulative dose was 3.1 mGy (range 0.2–16.4). Median estimated effective dose to the patient was 0.22 mSv (range 0.0–0.7). The effective dose of radiation was reduced by 80% (0.22 mSv vs. 1.11 mSv) compared to low-dose O-arm. The surgical team did not receive any detectable radiation. The seconds of PF used to assist and confirm placement of PSs was reduced to 1.2 s/level compared to previous reports of 4.49 s/level using SIs. DPMPs reduced fluoroscopy to 0.84 s/PS compared to 7.36 s/PS using SIs to assist and confirm PS placement. PSs were accurately placed in 561 of 576 (97.4%), which is comparable to O-arm and fluoroscopy with SIs. Conclusions PS placement using PF and DPMPs to assist and confirm PS placement lowers radiation exposure to the patient and surgical team without compromising accuracy compared to O-arm and fluoroscopy with SIs. Level of evidence Therapeutic, Level IV (Retrospective case series, historical control).

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3