Prosthetic replacement of the radial head

Author:

Wegmann Kilian,Ott Nadine,Leschinger Tim F.,Harbrecht Andreas,Müller Lars P.,Hackl Michael

Abstract

Abstract Background Radial head replacement is an established option in patients with comminuted radial head fractures and complex elbow trauma. While studies demonstrated that asymptomatic radiolucencies around the stem are common, the incidence and clinical significance of bone loss at the proximal part of the radius, just distal to the neck of the prosthesis (collar resorption), is unknown. Objectives The aim of this retrospective study was to analyse the incidence of collar resorption after radial head replacement and investigate whether this correlates with specific patient characteristics such as gender, age, indication for index surgery and the size of implant used. Materials and methods The study group consisted of 30 patients (average age 60.1 years) having undergone prosthetic replacement with a monopolar press-fit implant of the radial head at an average follow-up of 23 months. Indications for surgery included trauma sequelae or revision in 16 patients and acute, unreconstructable fractures of the radial head in 14 cases. Symptoms of loosening and revision surgery were recorded. Radiographs were analysed for signs of lucency between the bone and the implant as well as for signs of resorption of bone mass around the neck (section 1). These values were correlated with age, gender, indication for index surgery and size of implant. Results In all, 28/30 (93.3%) prostheses showed proximal osteolysis around the neck of the shaft. Of the 30, one prosthesis presented signs of shaft loosening. The average amount of osteolysis was 8.78% (range 0–26.1%; ±6.0%) of the overall length of the prosthetic shaft (OL). There was no significant difference (p = 0.49) between the amount of resorption in section 1 between the primary fracture cases (8.75 ± 4.5%; range 1.2–15.8%) and the group of secondary implantations due to degeneration or fracture sequelae (8.8 ± 7.2%; range 0–26.1%). Furthermore, the analysis did not reveal any statistically relevant correlations between the amount of neck resorption and the other cohort characteristics (age, gender, size of the components). Conclusions In the study cohort, a high amount of osteolysis/bone resorption was assessed around the neck of the press-fit radial head prosthesis used. However, no significant correlation between collar resorption, patient demographics and indication for index surgery was found at short-term follow-up.

Funder

Universitätsklinikum Köln

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3