Validation of Non-invasive Measurement of Cardiac Output: Using Whole-Body Bio-impedance Versus Inert Gas Rebreathing in Healthy Women Undergoing In Vitro Fertilisation

Author:

Jaspal Raj-Kamael,Allen Mae,Cornette Jerome,Rizopoulos Dimitris,Lees Christoph

Abstract

Abstract Background Haemodynamic assessment in and before pregnancy is becoming increasingly important in relation to pregnancy complications and outcomes. Different methodologies exist but there is no gold-standard technique for non-invasive measurement of cardiac output (CO). We sought to assess two methods of CO measurement in healthy women undergoing in vitro fertilisation cycles (IVF). This was a prospective longitudinal study of 71 women aged 18–44 years planning IVF undergoing CO measurements obtained via inert gas rebreathing (IGR) using Innocor and whole-body bio-impedance (WBI) using Nicas to assess the reproducibility between the methods. Four visits occurred at which both techniques were used: initial assessment, embryo transfer, day of pregnancy test and 4 weeks post-transfer (regardless of whether conception occurred). Cross-sectional agreement of the methods was assessed using the calculation of bias, percentage error and limits of agreement (LOA) via the Bland–Altman analysis. Longitudinal agreement of the methods was assessed using a 4-quadrant plot with concordance rate, angular bias and radial limits of agreement (%). Results One hundred and thirteen measurements from 44 participants were suitable for cross-sectional (Bland–Altman) analysis. IGR (Innocor) Mean CO was 4.61 L/min and 5.05 L/min with WBI (Nicas). The bias was 0.44 L/min. The percentage error was 76% and intra-correlation coefficient was 0.135 (95% CI −0.43–0.306). Fifty-nine measurements from 28 participants were suitable for longitudinal (4Q-plot) analysis. The concordance rate was 64.4%, angular bias – 0.14, and radial limits of agreement + − 13.25°. Conclusion There was poor cross-sectional and longitudinal agreement between inert gas rebreathing and whole-body bio-impedance techniques. These techniques cannot be used interchangeably when measuring CO in women undergoing IVF, and these results may be more generalizable, to women in the peri-conception period.

Funder

Imperial Health Charity

Publisher

Springer Science and Business Media LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3