Abstract
Abstract
Introduction
Graves' disease is an autoimmune disorder. Goiter and Graves' orbitopathy are frequently seen clinically. It would be helpful for the diagnosis, grading, prognosis, and treatment of this condition if it was possible to find serum biomarkers to establish a connection between the plasma levels of these compounds and orbital changes.
Methods
A retrospective study was performed by revising the medical records of 44 patients with Graves' orbitopathy and 15 controls. The Osirix software (Pixmeo, Geneva, Switzerland) was used for manual orbital measurements. Plasma levels of Graves' orbitopathy substances were obtained in the analytical review of the patients.
Results
A greater muscle volume was observed in patients with Graves' orbitopathy in relation to the control group (p < 0.001). The clinical activity score (CAS) was associated to total muscle mass (p = 0.013) and retrorbital fat (p = 0.048). Our results indicated a direct relationship between serum concentrations of anti-thyroid peroxidase antibodies and inferior rectus thickening (p = 0.036); however, we did not observe a positive correlation between other muscle volumes and serum concentrations of various thyroid-related substances.
Conclusions
This study is the first that uses Osirix measurement software to manually assess orbital features in patients with Graves' orbitopathy. These measurements were compared to the outcomes of tests performed in a laboratory. Among several serum biomarkers, anti-thyroid peroxidase appears to be a reliable biomarker that correlates positively with inferior rectus muscle thickness in patients with thyroid eye disease. This may help to improve the management of this disease.
Funder
This work was financially supported by ISCIII
European Union
Universidade de Santiago de Compostela
Publisher
Springer Science and Business Media LLC
Reference24 articles.
1. Smith TJ, Hegedus L (2016) Graves’ disease. N Engl J Med 375(16):1552–1565. https://doi.org/10.1056/NEJMra1510030
2. Tian S, Nishida Y, Isberg B, Lennerstrand G (2000) MRI measurements of normal extraocular muscles and other orbital structures. Graefe’s Arch Clin Exp Ophthalmol 238(5):393–404. https://doi.org/10.1007/s004170050370
3. Demer JL, Kerman BM (1994) Comparison of standardized echography with magnetic resonance imaging to measure extraocular muscle size. Am J Ophthalmol 118(3):351–361. https://doi.org/10.1016/s0002-9394(14)72960-5
4. Nishida Y, Aoki Y, Hayashi O, Murata T, Nishida E, Kani K (1996) Volume measurement of horizontal extraocular muscles with magnetic resonance imaging. Jpn J Ophthalmol 40(3):439–446
5. Bailey CC, Kabala J, Laitt R, Weston M, Goddard P, Hoh HB et al (1993) Cine magnetic resonance imaging of eye movements. Eye 7(Pt 5):691–693. https://doi.org/10.1038/eye.1993.157
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献