Intravitreal fluocinolone acetonide 0.19 mg (ILUVIEN®) in patients with non-infectious uveitis: real-world effectiveness and safety outcomes at 12 months

Author:

Moll-Udina AinaORCID,Hernanz Inés,Sainz-de-la-Maza Maite,Pelegrín Laura,Coelho-Borges Ana Isabel,Pazos Marta,Adán Alfredo,Llorenç Victor

Abstract

Abstract Purpose This study assessed the effectiveness of the 0.19-mg fluocinolone acetonide (FAc) implant by multimodal measurements in patients with non-infectious uveitis (NIU) in a real-world setting in Spain. Methods A prospective study of patients who had NIU including uveitic macular oedema (UME) with ≥ 12 months follow-up was done. Exclusion criteria include infectious uveitis and uncontrolled glaucoma or ocular hypertension requiring more than 2 medications. Effectiveness was assessed using a multicomponent outcome measure that included nine outcomes. Effectiveness was defined as all components being met at every timepoint. Secondary outcome measures were onset or progression of glaucoma and investigator-reported adverse events. Results Twenty-six eyes from 22 patients were included, with 96.2% having an indication including UME. During the 12-month study, the FAc implant was effective in 15 (57.7%) eyes, reaching effectiveness as soon as 2 weeks post-implantation. Mean best-corrected visual acuity and mean central macular thickness (CMT) were significantly improved vs. baseline at all timepoints (all comparisons p < 0.01). During the 12-month study, inflammation markers (anterior chamber cells and vitreous haze) had also significantly declined. Factors predicting effectiveness at month 12 were systemic corticosteroid dose pre-FAc, higher immunomodulatory therapy (IMT) load at baseline and thicker retinal nerve fibre layer (RNFL) at baseline (all p < 0.05). Factors predicting failure were male gender, thinner RNFL at baseline and treatment ineffectiveness at 1 month (all p < 0.05). In parallel, corticosteroid and IMT use also declined significantly. No significant increase in IOP was detected. Conclusion The FAc implant is safe and effective at treating NIU over 12 months in a real-world setting in Spain.

Funder

FCT – Fundação para a Ciência e Tecnologia

Universitat de Barcelona

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3