Measurement of the distance between tumor micro-foci and gross tumor in rectal cancer pathological specimens: implication on margin distance of clinical target volume treated with high-dose radiotherapy for rectal cancer

Author:

Bao Xu-Jie,Chen Xiao-Yan,Wen Lu,Liu Yuan-Yuan,Yu En-Hao,Wu Zheng,Liu Ke,Zhou Ju-Mei,Zhu Su-YuORCID

Abstract

Abstract Purpose To measure the micro-foci distance away from gross tumor and to provide reference to create the clinical target volume (CTV) margin for boost radiotherapy in rectal adenocarcinoma. Methods Twenty-eight rectal cancer surgical specimens of only total mesorectal excision were collected. The pathological specimens were retrospectively measured, and the nearest distance between the tumor micro-foci and gross tumor was microscopically measured. The “in vivo–in vitro” retraction factor was calculated as the ratio of the deepest thickness laterally and the vertical height superior/inferiorly of the rectal tumor measured in MRI and those measured in immediate pathological specimens. The retraction factor during pathological specimen processing was calculated as the distance ratio before and after dehydration in the lateral, superior, and inferior sides by the “knot marking method.” The distances of tumor micro-foci were individually corrected with these two retraction factors. Results The mean “in vivo–in vitro” tumor retraction factors were 0.913 peripherally and 0.920 superior/inferiorly. The mean tumor specimen processing retraction factors were 0.804 peripherally, 0.815 inferiorly, and 0.789 superiorly. Of 28 patients, 14 cases (50.0%) had 24 lateral micro-foci, 8 cases (28.6%) had 13 inferior micro-foci, and 7 cases (25.0%) had 19 superior micro-foci. The 95th percentiles of the micro-foci distance for 28 patients were 6.44 mm (peripheral), 5.54 mm (inferior), and 5.42 mm (superior) after retraction correction. Conclusion The micro-foci distances of 95% of rectal adenocarcinoma patients examined were within 6.44 mm peripherally, 5.54 mm inferiorly, and 5.42 mm superiorly. These findings provide reference to set the boost radiotherapy CTV margin for rectal cancer.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3