Biomechanical evaluation of the proximal chevron osteotomy in comparison to the Lapidus arthrodesis for the correction of hallux valgus deformities

Author:

Kasparek Maximilian F.,Benca Emir,Hirtler Lena,Willegger Madeleine,Boettner Friedrich,Zandieh Shahin,Holinka Johannes,Windhager Reinhard,Schuh Reinhard

Abstract

Abstract Purpose The proximal chevron osteotomy and the modified Lapidus arthrodesis are both procedures utilized for deformity correction in patients with severe symptomatic hallux valgus. The aim of the current study was to compare their biomechanical stability when using locking plate fixation. Methods Twelve matched pairs of human anatomical lower leg specimens underwent on one side a proximal chevron osteotomy with a medial locking plate and on the other side a modified Lapidus arthrodesis with a plantar locking plate utilizing an interfragmentary compression screw. All specimens underwent bone mineral density (BMD) assessment and were tested in a servohydraulic load frame which applied a load on the centre of the metatarsal head over 1000 loading cycles with subsequently ultimate load testing. Displacement of the proximal and distal bone segment, ultimate load, and bending stiffness were analyzed. Results Mean displacement of both procedures showed no statistically significant difference throughout all the loading cycles (0.213 ≤ p ≤ 0.834). The mean ultimate load of the proximal chevron osteotomy was 227.9 N (± 232.4) and of the modified Lapidus arthrodesis 162.9 N (± 74.6) (p = 0.754). The proximal chevron osteotomy (38.2 N/mm (± 24.9)) had a significantly higher bending stiffness compared to the modified Lapidus arthrodesis (17.3 N/mm (± 9.9)) (p = 0.009). There was no correlation between BMD and displacement in all loading cycles, ultimate load, and bending stiffness of either procedure (p > 0.05). Conclusion Although the bending stiffness of the chevron osteotomy was higher, there was no statistically significant difference between the surgical techniques in mean displacement and ultimate load. The BMD did not influence the overall stability of either reconstruction. Locking plate fixation increases the clinical value of the modified Lapidus arthrodesis by outweighing most of the biomechanical disadvantages in comparison to the proximal chevron osteotomy.

Funder

Medical Scientific Fund of the Mayor of the City of Vienna

Medical University of Vienna

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3