Development of open access tool for automatic use factor calculation using DICOM-RT patient data

Author:

Choi Dong Hyeok,Kim Dong Wook,Park So Hyun,Ahn So HyunORCID,Ahn Woo Sang,Lee Rena,Kim Jin Sung

Abstract

AbstractOur study recalculated the use factor of linear accelerators (LINACs) by using an in-house program based on Digital Imaging and Communications in Medicine radiation therapy (DICOM-RT). We considered the impact of advancements and changes in treatment trends, including modality, technology, and radiation dose, on the use factor, which is one of the shielding parameters. In accordance with the methodology described in the NCRP 151 report, we computed the use factor for four linear accelerators (LINACs) across three hospitals. We analyzed the results based on the treatment techniques and treatment sites for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy or volumetric modulated arc therapy. Our findings revealed that the use factors obtained at 45° and 90° were 14.8% and 13.5% higher than those of the NCRP 151 report. In treatment rooms with a high 3D-CRT ratio, the use factor at a specific angle differed by up to 14.6% relative to the NCRP 151 report value. Our results showed a large difference in the use factor for specific sites such as the breast and spine, so it is recommended that each institution recalculate the use factor using patient’s data.

Funder

Korea Institute of Energy Technology Evaluation and Planning

Basic Science Research Program through the National Research Foundation of Korea

Gangneung Asan Hospital

Future innovation-based technology radiation research

Korea Foundation of Nuclear Safety

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Biophysics,Radiological and Ultrasound Technology,Biotechnology

Reference32 articles.

1. Cho YR, Jung H, Lee DH (2018) On the use factor analysis and adequacy evaluation of CyberKnife Shielding Design using Clinical Data. Progress in Medical Physics 29:115–122. https://doi.org/10.14316/pmp.2018.29.4.115

2. Kaur A, Pawaskar P, Sahani G (2018) Mathematical approach in determining use factor for equipment with rotational dose delivery technique. J Med Phys 43:30

3. National Committee on Radiation Protection and Measurements (1961) Medical X-ray protection up to three million volts: recommendations of the National Committee on Radiation Protection and Measurements.

4. Burnett BM (1971) NCRP Report No. 34. Medical X-Ray and Gamma-Ray Protection for Energies up to 10 MeV: structural shielding design and evaluation. National Council on Radiation Protection and measurements. New York, p 101.

5. Protection NCoR Measurements (1976) Structural shielding design and evaluation for medical use of X-rays and Gamma Rays of energies up to 10 MeV: recommendations of the National Council on Radiation Protection and measurements. The Council

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3