Development of open access tool for automatic use factor calculation using DICOM-RT patient data
-
Published:2023-07-20
Issue:3
Volume:46
Page:1043-1053
-
ISSN:2662-4729
-
Container-title:Physical and Engineering Sciences in Medicine
-
language:en
-
Short-container-title:Phys Eng Sci Med
Author:
Choi Dong Hyeok,
Kim Dong Wook,
Park So Hyun,
Ahn So HyunORCID,
Ahn Woo Sang,
Lee Rena,
Kim Jin Sung
Abstract
AbstractOur study recalculated the use factor of linear accelerators (LINACs) by using an in-house program based on Digital Imaging and Communications in Medicine radiation therapy (DICOM-RT). We considered the impact of advancements and changes in treatment trends, including modality, technology, and radiation dose, on the use factor, which is one of the shielding parameters. In accordance with the methodology described in the NCRP 151 report, we computed the use factor for four linear accelerators (LINACs) across three hospitals. We analyzed the results based on the treatment techniques and treatment sites for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy or volumetric modulated arc therapy. Our findings revealed that the use factors obtained at 45° and 90° were 14.8% and 13.5% higher than those of the NCRP 151 report. In treatment rooms with a high 3D-CRT ratio, the use factor at a specific angle differed by up to 14.6% relative to the NCRP 151 report value. Our results showed a large difference in the use factor for specific sites such as the breast and spine, so it is recommended that each institution recalculate the use factor using patient’s data.
Funder
Korea Institute of Energy Technology Evaluation and Planning
Basic Science Research Program through the National Research Foundation of Korea
Gangneung Asan Hospital
Future innovation-based technology radiation research
Korea Foundation of Nuclear Safety
Publisher
Springer Science and Business Media LLC
Subject
Radiology, Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Biophysics,Radiological and Ultrasound Technology,Biotechnology
Reference32 articles.
1. Cho YR, Jung H, Lee DH (2018) On the use factor analysis and adequacy evaluation of CyberKnife Shielding Design using Clinical Data. Progress in Medical Physics 29:115–122. https://doi.org/10.14316/pmp.2018.29.4.115
2. Kaur A, Pawaskar P, Sahani G (2018) Mathematical approach in determining use factor for equipment with rotational dose delivery technique. J Med Phys 43:30
3. National Committee on Radiation Protection and Measurements (1961) Medical X-ray protection up to three million volts: recommendations of the National Committee on Radiation Protection and Measurements.
4. Burnett BM (1971) NCRP Report No. 34. Medical X-Ray and Gamma-Ray Protection for Energies up to 10 MeV: structural shielding design and evaluation. National Council on Radiation Protection and measurements. New York, p 101.
5. Protection NCoR Measurements (1976) Structural shielding design and evaluation for medical use of X-rays and Gamma Rays of energies up to 10 MeV: recommendations of the National Council on Radiation Protection and measurements. The Council
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献